3-4
KLP070312
3.2.2.1
REMOTE WITH LOCAL (FRONT PANEL) LOCKOUT
To prevent unauthorized setting of the power supply to Local mode, a local lockout mode can be
enabled which prevents the power supply from being restored to local mode via the front panel.
With the power supply turned off, set the ANALOG I/O DIP switch, position 5 (see Table 2-2) to
ON. Now when the power supply is turned on the status display will read one of the following:
LOCK
- front panel controls locked, analog mode not enabled and no digital commands received.
aRwl
(analog Remote with local lockout) - front panel controls locked, analog mode enabled
dRwl
(digital Remote with local lockout) - front panel controls locked, analog mode disabled and
a digital command received.
Once the front panel is locked, it can only be unlocked by either of the following:
• turn the power supply off, set ANALOG I/O DIP switch position 5 to OFF, and then
power up again.
• send the following SCPI command via GPIB, RS 232 or LAN port:
SYST:KLOC OFF
NOTE: If the front panel is unlocked by SCPI command, the unit will be set to Remote
with Local Lockout when it is turned on again. Set ANALOG I/O DIP switch posi-
tion 5 to OFF to disable Remote with Local Lockout.
3.2.3
MENU STRUCTURE
Many KLP functions are accessed via the
FUNCTION
switch. This switch is disabled when the
unit is in setpoint mode (If the status display shows
SET
, tap either the
CURRENT
or
VOLTAGE
controls to take the unit out of setpoint mode (status display goes from
SET
to blank).
Pressing
FUNCTION
switch using a thin tool (e.g., a paper clip) accesses the menu and sub-
menu structure indicated on the four-character status display (see Figure 3-1). To scroll through
menu and submenu selections rotate either the
DC VOLTS
or
DC AMPERES
control. Tap the
DC OUTPUT
switch to select and proceed. Exit any submenu by tapping the
DC OUTPUT
switch when the status display shows
RTN
to return to the previous menu. To exit the Function
menu after all submenus have been exited, tap the
DC OUTPUT
switch when the status display
shows
EXIT
. Pressing the
FUNCTION
switch once within any menu or submenu will also exit
the Function menu.
3.2.4
VOLTAGE AND CURRENT CONTROL COARSE/FINE PREFERENCE
The
VOLTAGE
or
CURRENT
controls are shipped from the factory so that rotating either con-
trol produces a coarse adjustment; pressing the control in while rotating produces a fine adjust-
ment.
Содержание KLP 10-150-2
Страница 2: ......
Страница 6: ......
Страница 12: ...vi KLP070312 FIGURE 1 1 KLP SERIES POWER SUPPLY...
Страница 19: ...KLP 070312 1 7 FIGURE 1 3 KLP SERIES POWER SUPPLY MECHANICAL OUTLINE DRAWING SHEET 1 OF 2...
Страница 20: ...1 8 KLP 070312 FIGURE 1 3 KLP SERIES POWER SUPPLY MECHANICAL OUTLINE DRAWING SHEET 2 OF 2...
Страница 27: ...KLP HV 070312 2 3 FIGURE 2 2 KLP SERIES REAR PANEL SWITCH AND CONNECTORS...
Страница 40: ......
Страница 78: ......
Страница 90: ......