2-2

KLP-HV 070312

2.2.2

REAR PANEL CONNECTORS AND SWITCHES. 

 Refer to Figure 2-2 and Tables 2-2 through

2-7.

DC AMPERES

display

Four-digit LED display that shows current settings:
a. Shows actual output current (PAR.3.2.9).
b. Shows current set point or overcurrent limit when function selected (PAR. 3.2.9.2).
c. Shows GPIB address (PAR. 3.2.11), baud rate (PAR. 3.2.12).
d. Shows unit password (PAR. 3.2.8 and PAR. 4.3).

CURRENT

control/

momentary switch

Multifunction rotary encoder with momentary-contact pushbutton switch. Rotate to set output current 
(PAR. 3.2.9) and overcurrent limit (PAR. 3.2.10). Also used to enter SET mode of current programming 
(PAR. 3.2.9.2), change GPIB address (PAR. 3.2.11), change RS 232 baud rate (PAR. 3.2.12), enter 
Virtual Model password (PAR. 3.2.8), and enter calibration password and perform calibration (PAR. 
4.3).

DC OUTPUT

indicator

Green LED lights when DC output is enabled. LED is off when output is disabled.

DC OUTPUT

on/off switch

Enables or disables the DC Output. When output is disabled, current and voltage are programmed to 
minimal value and zero, respectively (PAR. 3.2.5). Also used to accept front panel inputs.

PROTECT

momentary switch

Used to set overvoltage and overcurrent (PAR. 3.2.10) protection limits. 
NOTE: Requires a thin tool (e.g., end of paper clip) to press switch.

LAN Indicator

[E-Series models only]

Green LED indicates when LAN interface is installed and valid IP address found. Can be intentionally 
blinked using the web-based interface to identify which unit is being accessed in a multi-unit environ-
ment. During initialization the LED blinks rapidly while attempting to locate a valid IP address. If suc-
cessful, LED stays on without blinking; LED not lit indicates failure.

FUNCTION

momentary switch

Used to set user-determined limits on voltage and current (virtual model) (PAR. 3.2.8), view KLP con-
figuration (Firmware Version, Model rating, Options installed) (PAR. 3.2.15), change GPIB address 
(PAR. 3.2.11), change RS 232 baud rate (standard models only, PAR. 3.2.12), set up master/slave 
operation (standard models only, PAR. 3.2.13), set up LAN interface (E-Series models only, PAR. 
3.2.14), and enter the Utility menu (PAR. 3.2.16). The utility menu is used to configure the internal 
relay (PAR. 3.2.16.1), configure quick-boot (PAR. 3.2.16.2), configure Remote Inhibit (high or low) and 
determine how the unit responds to faults (PAR. 3.2.16.3), calibrate analog inputs (PAR. 3.2.16.4), and 
enter calibration (PAR. 4.3). NOTE: Requires a thin tool (e.g., end of paper clip) to press switch.

TABLE 2-2.  ANALOG I/O SWITCH FUNCTIONS

DIP SWITCH 

POSITION

FUNCTION

SETTINGS

1

Allows analog programming commands for 

voltage

 to be provided 

by either variable voltage (PAR. 3.4.3) or resistance (PAR. 3.4.2). 

ON:

Selects Resistance

OFF: Selects Voltage (factory 

default)

2

Allows analog programming commands for 

current

 to be provided 

by either variable voltage (PAR. 3.4.3) or resistance (PAR. 3.4.2). 

ON: Selects 

Resistance

OFF: Selects Voltage (factory 

default)

3

Allows retention of the last entered setpoint values for voltage and 
current in non-volatile memory for recall at the next power-up 
sequence. (see PAR. 3.2.9.3). 

ON: 

Save and recall previous set-
point values upon power-up.

OFF: Power-up set to 0 Volts and 

minimum current (factory 
default).

4

Reserved - Do not use.

5

Allows locking of the front panel controls. (see PAR. 3.2.2.1)

ON:

Local controls locked.

OFF: Local controls enabled (fac-

tory default).

TABLE 2-1.  CONTROLS, AND INDICATORS (CONTINUED)

CONTROL OR 

INDICATOR

FUNCTION

Содержание KLP 10-150-2

Страница 1: ...ON NOTE 2 A Change Page may be included at the end of the manual All applicable changes and revision number changes are documented with reference to the equipment serial num bers Before using this Ins...

Страница 2: ......

Страница 3: ...nd Address KEPCO INC 131 38 SANFORD AVENUE FLUSHING N Y 11352 USA Importer s Name and Address Type of Equipment Component Power Supply Model No PRODUCT MODEL NUMBER Year of Manufacture I the undersign...

Страница 4: ...wire grounded mains connection See wiring section of this manual for complete electrical wiring instructions EN 61010 1 2001 Cl 6 10 1 4 This power supply has secondary output circuits that are consid...

Страница 5: ...orming any servicing The PROTECTIVE EARTHING CONDUCTOR TERMINAL must be properly con nected prior to application of source power to the product see instructions on instal lation herein in order to ens...

Страница 6: ......

Страница 7: ...2 1 Unpacking and Inspection 2 1 2 2 Terminations and Controls 2 1 2 2 1 Front Panel Controls and Indicators 2 1 2 2 2 Rear Panel Connectors and Switches 2 2 2 3 Source Power Requirements 2 6 2 4 Coo...

Страница 8: ...3 1 Remote Inhibit Configuration 3 18 3 2 16 3 2 Fault Recovery Configuration 3 18 3 2 16 4 Analog Output Full Scale Calibration 3 20 3 2 16 5 Analog Input Full Scale Calibration 3 21 3 2 16 6 Calibr...

Страница 9: ...4 1 General 4 1 4 2 Equipment Required 4 1 4 3 Calibration Using Front Panel Controls in Local Mode 4 2 4 3 1 Voltage Calibration Local 4 2 4 3 2 Current Calibration Local 4 3 4 3 3 External Calibrat...

Страница 10: ...3 4 Setting a Static IP Address 3 25 3 5 Web Interface Home Page Unit Description 3 26 3 6 Web Interface Configure Instrument Page 3 27 3 7 Web Interface Configure LAN Page 3 28 3 8 Web Interface Oper...

Страница 11: ...ators 2 1 2 2 Analog I O Switch Functions 2 2 2 3 IEEE 488 Port Connector J4 Pin Assignments 2 4 2 4 RS 232 Port Connector J3 Pin Assignments Standard Models Only 2 4 2 5 LAN Port Connector J7 Pin Ass...

Страница 12: ...vi KLP070312 FIGURE 1 1 KLP SERIES POWER SUPPLY...

Страница 13: ...nly difference between standard and E Series models is that LAN replaces the RS 232 interface on E Series models All models allow remote analog programming as well as local control For each model a mu...

Страница 14: ...pen circuit output The RODC circuit will support continuous repetitive discharges from rated model voltage to zero at rate of up to 1 Hz for the 10V 20V and 36V models and up to 0 5 Hz for the 75V 150...

Страница 15: ...120A 10V 120A 60 mV 82 KLP 36 60 3 0 36V 33 3A 36V 0 8A 0 60A 20V 60A 60 mV 83 KLP 75 33 3 0 75V 16A 75V 0 4A 0 33 3A 36V 33 3A 60 mV 84 KLP 150 16 3 0 150V 8A 150V 0 2A 0 16A 75V 16A 125 mV 86 KLP 3...

Страница 16: ...No minimum load required current minimum to 100 of rated current No minimum load required See Table 1 2 for minimum programmable current Source effect voltage 0 01 Emax Over full source range current...

Страница 17: ...e gral threaded stud 1 4 20 1 2in Provision for safety covers 75 600V models Shock safe Euroblock single conduc tor size 20 10AWG 0 5 5 0 mm 2 Analog programming port 15 pin D sub Digital programming...

Страница 18: ...nd RS 232 see KLP Developer s Guide E Series models GPIB and LAN Support SCPI command set see KLP Developer s Guide for GPIB and LAN Support four interfaces for LAN 1 Web interface port 80 LXI Class C...

Страница 19: ...KLP 070312 1 7 FIGURE 1 3 KLP SERIES POWER SUPPLY MECHANICAL OUTLINE DRAWING SHEET 1 OF 2...

Страница 20: ...1 8 KLP 070312 FIGURE 1 3 KLP SERIES POWER SUPPLY MECHANICAL OUTLINE DRAWING SHEET 2 OF 2...

Страница 21: ...mmands or via the LAN port using SCPI com mands or web pages Most features available in local mode can be accessed in remote mode through digital programming as well as some that are only available vi...

Страница 22: ...100 memory locations for programming sequences that can program the KLP to produce a variety of sequential output operations Each memory location accommodates a value for voltage and current and a dw...

Страница 23: ...le standard KLP power supplies in either series for higher voltage or parallel for redundancy or higher current the master slave feature allows a single power supply the master to automatically contro...

Страница 24: ...488 2 IEEE 488 GPIB Cable 4m long Connect KLP Power Supply to GPIB bus SNC 488 4 Chassis Slide 2 required per power supply Allows rack mounted units to slide in and out 108 0239 Jonathan 375 QD Serie...

Страница 25: ...2 9 and overvoltage limit PAR 3 2 10 Also used to enter SET mode of voltage program ming PAR 3 2 9 2 change GPIB address PAR 3 2 11 change RS 232 baud rate PAR 3 2 12 enter Virtual Model password PAR...

Страница 26: ...ress If suc cessful LED stays on without blinking LED not lit indicates failure FUNCTION momentary switch Used to set user determined limits on voltage and current virtual model PAR 3 2 8 view KLP con...

Страница 27: ...KLP HV 070312 2 3 FIGURE 2 2 KLP SERIES REAR PANEL SWITCH AND CONNECTORS...

Страница 28: ...mmon 22 GND Ground signal common 23 GND Ground signal common 24 LOGIC GND Logic Ground TABLE 2 4 RS 232 PORT CONNECTOR J3 PIN ASSIGNMENTS STANDARD MODELS ONLY PIN SIGNAL NAME FUNCTION NOTE A null mode...

Страница 29: ...ch position 1 See Table 2 2 Refer to PAR 3 4 3 for voltage programming and 3 4 2 for resistance programming 4 RELAY_COM Relay common 1 5 Reserved 6 VOLT_RBACK Analog signal which represents output vol...

Страница 30: ...able to ascertain whether the power supply has suffered damage resulting from shipping Refer to Figures 2 1 and 2 2 for location of operating controls and electrical connections Table 2 1 explains the...

Страница 31: ...e output Verify DC OUTPUT indicator lights 8 Compare the programmed output voltage value step 5 with the voltage reading of the DVM the difference between the two should not exceed 0 05 of the maximum...

Страница 32: ...under worst case efficiency conditions at the lowest rated source voltage 90V a c and provides the necessary overload protection to the power supply s internal circuitry The user must provide a prope...

Страница 33: ...ound point is entirely dependent upon the specific applica tion and its selection requires a combination of analysis good judgement and some amount of empirical testing If there is a choice in selecti...

Страница 34: ...ic output response of the power supply is critical to load performance 2 7 5 LOAD CONNECTION GENERAL Power connections to the load are achieved via the and DC OUTPUT terminals located on the rear pane...

Страница 35: ...While KLP power supplies may be configured for series operation the complexities of external interconnections make parallel operation the superior choice for achieving higher output power levels in al...

Страница 36: ...2 12 KLP HV 070312 FIGURE 2 4 SERIES CONNECTION USING REMOTE SENSING FIGURE 2 5 PARALLEL CONNECTIONS USING REMOTE SENSING 2 7 6...

Страница 37: ...triplets to daisy chain the S CS and S terminals to the first power supply For remote error sensing the same procedure is followed as for local sensing except that the local error sense jumpers are re...

Страница 38: ...or all analog programming inputs and status signal outputs In addition an external trigger input is available for use with SCPI TRG and TRIG commands Refer to Table 2 7 for analog I O programming sign...

Страница 39: ...Table 2 3 for GPIB port pin assignments Refer to PAR 3 2 11 to change the default GPIB address 6 from the front panel 2 8 2 RS 232 CONNECTIONS STANDARD MODELS ONLY Communications between KLP consider...

Страница 40: ......

Страница 41: ...isplays show set points and limits as well Status and fault indications are provided by a 4 character alpha numeric display 3 2 1 TURNING THE POWER SUPPLY ON 1 To turn the power supply on set POWER ON...

Страница 42: ...AMPERES displays show programmed output conditions either 0 Volts minimum Amperes see NOTE PAR 3 2 1 or if DIP switch position 3 enabled see Table 2 2 previously saved setpoint values in effect upon p...

Страница 43: ...emote digital mode The OPERATE INSTRUMENT web page E Series models only must not be active when restoring local mode To disable local mode entirely see PAR 3 2 2 1 for front panel lock out NOTE During...

Страница 44: ...when it is turned on again Set ANALOG I O DIP switch posi tion 5 to OFF to disable Remote with Local Lockout 3 2 3 MENU STRUCTURE Many KLP functions are accessed via the FUNCTION switch This switch i...

Страница 45: ...as no effect If output was on while setpoint mode was entered pressing DC OUTPUT will disable the output For setpoint adjustment refer to PAR 3 2 9 2 To enable disable the output using analog control...

Страница 46: ...us display reads ERR Repeat this step to enter the correct password or press the FUNCTION switch to exit 3 2 8 DEFINING A VIRTUAL MODEL The virtual model is defined by establishing a maximum programma...

Страница 47: ...upply accept limits beyond its maximum ratings of voltage and current As the primary parameter is increased the power supply will automatically decrement the secondary parameter as necessary to mainta...

Страница 48: ...ely 20 seconds Tap either adjustment control again to accept the displayed setting 2 In the setpoint mode both coarse and fine adjustment are available see PAR 3 2 3 to set coarse fine preference The...

Страница 49: ...el is defined PAR 3 2 8 OVP and OCP are automatically set 20 and 20 respectively above the maximum programmable values established by the virtual model If OVP or OCP are lowered by the user valid sett...

Страница 50: ...e then tap the DC OUTPUT switch to accept the displayed baud rate The display briefly reads DONE then returns to BAUD 5 Rotate the VOLTAGE control until display reads EXIT then tap the DC OUTPUT switc...

Страница 51: ...IGURE POWER SUPPLY AS MASTER STANDARD MODELS ONLY 1 Turn power on If the unit comes up in setpoint mode see PAR 3 2 6 tap either the CUR RENT or VOLTAGE controls to take the unit out of setpoint mode...

Страница 52: ...show the total values for set point voltage and current readback virtual model the virtual model and protection settings of the slave are automatically programmed to be the same as the master and pro...

Страница 53: ...til DC AMPERES display shows 1 Rotate the VOLTAGE control until DC VOLTS display shows 1 5 Press DC OUTPUT to accept the displayed settings The unit briefly flashes WAIT then restarts with the new set...

Страница 54: ...VOLTS display shows 45 and the DC AMPERES display shows 67 Cannot be changed by the user MAC3 Shows third pair of hex digits of the MAC address e g for MAC address 01 23 45 67 89 AB the DC VOLTS displ...

Страница 55: ...KLP 75 33 This information cannot be changed by the user If the status display reads RODC this indicates the unit is an R Option model that has RODC Rapid Output Discharge Circuit installed If the sta...

Страница 56: ...LY The DC VOLTS display indicates whether the relay is currently ON energized or OFF deenergized Tap DC OUTPUT switch to enter Relay Control menu Rotate either VOLTAGE or CURRENT control to see the av...

Страница 57: ...lay state is displayed then tap the DC OUTPUT switch to immediately set the relay to the selected state and return to the RELY menu c To select LIST tap the DC OUTPUT switch to save selection unit ret...

Страница 58: ...CURRENT control until status display reads RTN then tap DC OUTPUT switch to return to next highest menu 3 2 16 3 2 FAULT RECOVERY CONFIGURATION The KLP allows the user to control how the unit recovers...

Страница 59: ...cing circuits powered by the output always switch the KLP front panel circuit breaker OFF If more than one fault occurs the fault with the lowest risk level determines the unit s response however mult...

Страница 60: ...NALOG OUTPUT FULL SCALE CALIBRATION Enter UTIL menu see PAR 3 2 16 steps 1 through 3 and rotate either VOLTAGE or CUR RENT control until status display reads ANRB The DC VOLTS display shows the analog...

Страница 61: ...ON switch to cancel the operation 5 To exit rotate either VOLTAGE or CURRENT control until the status display reads RTN then tap the DC OUTPUT switch To exit the UTIL menu rotate either VOLTAGE or CUR...

Страница 62: ...available from the front panel Storage of User programmed Active Settings 40 memory locations are available to store and recall active settings of the power supply The active setting include voltage c...

Страница 63: ...server and get an IP address during this time the LAN indicator blinks rapidly If a server is found and an address assigned the LAN indicator stays on without blinking If the server is not found after...

Страница 64: ...the Kepco web site at www kepcopower com driv ers drivers dl3 htm klp This utility finds all operational Kepco power supplies connected to the LAN and then shows the pertinent addresses of the models...

Страница 65: ...indow is closed and a new window is opened Upon initial display of the web page it is good practice to click the browser Refresh Reload but ton once to ensure that the power supply information display...

Страница 66: ...age are Whether the polarity of the Remote Inhibit signal is active inhibit for low or high see PAR 3 2 16 3 1 for details How the unit recovers from faults see PAR 3 2 16 3 2 for details GPIB address...

Страница 67: ...ted There are three passwords shown on this page which control access to the web pages only not to be confused with the unit password see PAR 3 2 7 which is needed for calibration chang ing virtual mo...

Страница 68: ...checkboxes then click SUBMIT If the data is not entered within 20 seconds after the last keystroke the data will revert to the previous value If the LAN CONFIGURATION password was set you will be pro...

Страница 69: ...he fault is corrected click OK to close the alert window and resume operation via the web NOTE If the OPERATE INSTRUMENT password has been set see PAR 3 3 6 4 you will be prompted to enter the passwor...

Страница 70: ...bout how overvoltage and overcurrent protection function in the KLP power supply FIGURE 3 9 PROTECTION DIALOG BOX 3 3 6 6 3 USING SAVE AND RECALL E SERIES MODELS ONLY The KLP Power Supply contains 40...

Страница 71: ...nged and a stored setting is outside the range established by the new virtual model the data set is not loaded although there is no indication on the web page the Status Display of the power supply wi...

Страница 72: ...r forming any of the following operations will also clear the list changing overcurrent or overvolt age PROTECTION settings unit RESET clicking RST changing VIRTUAL MODEL settings and exiting the OPER...

Страница 73: ...6 6 SETTING VIRTUAL MODEL E SERIES MODELS ONLY Refer to PAR 3 2 8 for details about what Virtual Model means for KLP and how the virtual model affects other parameters Click VIRTUAL MODEL Figure 3 8...

Страница 74: ...ng resolution for virtual model settings that are less than the model maximum ratings Vmax and Imax as long as 10V analog input is equivalent to full scale Decreasing the analog voltage equivalent to...

Страница 75: ...al connections required for analog programming using an external resistance 1 Virtual model PAR 3 2 8 and Overvoltage and Overcurrent settings PAR 3 4 4 must be established via either local programmin...

Страница 76: ...local programming or digital remote programming prior to initiating Analog Remote programming 2 Turn off power and configure the Analog I O DIP switch Figure 2 2 as follows SW1 OFF Program output volt...

Страница 77: ...local mode from the front panel enter local mode by pressing the VOLTAGE and CURRENT adjustment controls at the same time then see PAR 3 2 10 If the panel is locked and RS 232 or GPIB access is not po...

Страница 78: ......

Страница 79: ...local mode PAR 4 3 4 or SAVE Calibration is executed remote mode PAR 4 4 4 Calibration of the KLP is performed in one of two ways locally using the front panel controls PAR 4 3 or remotely using the g...

Страница 80: ...CAL The last calibration date is displayed see PAR 4 3 4 for details and the DC AMPERES display reads 0000 with the left most digit blinking 7 Tap DC OUTPUT switch to enter calibration mode The status...

Страница 81: ...decrease the DVM reading until the DVM reading corre sponds to minimum positive or zero current Calculate current as follows I Amperes DVM reading Volts Shunt Resistance Ohms 4 Tap the DC OUTPUT swit...

Страница 82: ...next function as if the FUNCTION switch was pressed 1 When the status display reads EXIT tap the DC OUTPUT switch to save the calibration 2 The status display reads DATE The DC VOLTS display represent...

Страница 83: ...ed to the output of the power supply For current calibration after disconnecting all loads an appropriate shunt resistor will be connected across the output terminals and the digital voltmeter will be...

Страница 84: ...correct password or click the Calibrate Close button on the VXI main panel to exit calibration NOTE Calibrations may be done in any order 9 Proceed to PAR 4 4 1 for voltage calibration PAR 4 4 2 for...

Страница 85: ...ccept the value the status display now reads OUTV At the ANALOG I O PORT J2 connect the DVM M to pin 13 M to pin 6 and the d c power source V to pin 9 V to pin 3 set the d c source output to 10 00V Cl...

Страница 86: ...current as follows Amperes DVM reading Volts Shunt Resistance Ohms 4 Click the PRESS TO ACCEPT button to accept the value The status display reads CMAX Click the button to increase and the to decreas...

Страница 87: ...TO ACCEPT button to accept the value When the calibration is saved this analog voltage will be equivalent to full scale output voltage NOTE The full scale output voltage is determined by the virtual...

Страница 88: ...value corresponding to 1200 Watts 4 5 CHANGING THE CALIBRATION PASSWORD The 4 digit Unit password is required for to enter calibration mode The factory default Unit password is listed in Table 4 1 To...

Страница 89: ...alues are moved to Prior and the new calibration values are stored in Working The values in Working are the ones used by the power supply during operation Should the need arise it is possible to repla...

Страница 90: ......

Страница 91: ...mined by the load see PAR 3 2 5 How do I establish the operating mode Operating mode is determined automatically by the programmed voltage Vp and current Ip settings and the load If the load impedance...

Страница 92: ...ual model limits Programming inputs are only active when analog port is enabled See PAR 3 4 2 for details How do I Read back operating voltage and current Analog signals proportional to actual output...

Отзывы: