KLP 070312
1-5
GENERAL (ENVIRONMENTAL) SPECIFICATIONS
Temperature
operating
-20 to +50 deg C
Rated load. Derate at -25W per °C from
50°C to 70°C.
storage
-40 to +85 deg C
Cooling
3 internal d-c fans
exhaust to the rear
Humidity
0 to 95% RH
non-condensing
Shock
20g, /- 50% half sine
non-operating
Vibration
5 -10 Hz
10mm double amplitude
3-axes, non-operating
10-55 Hz
2g
3-axes, non-operating
Altitude
sea level to 10000 ft.
0-3,000 ft: 100%, linear derating to 70%
of power at 10,000ft.
PHYSICAL CHARACTERISTICS
Dimensions
English 1.735”H x 19"W x 17.5"D
Depth excluding connectors and termi-
nal blocks (see Figure 1-3).
metric 44.45 x 482.6 x 443.7 mm
Weight
English 15 lbs
metric 6.82kg
Source power connector
IEC 320-C19 appliance inlet
250 Va-c, 16A (VDE);
125V a-c, 20A (UL)
Load connections
10-36V models Nickel plated copper busbar with inte-
gral threaded stud (1/4-20-1/2in.)
Provision for safety covers.
75-600V models Shock-safe Euroblock, single conduc-
tor size: 20-10AWG (0,5 - 5,0 mm2)
Analog programming port.
15 pin D-sub
Digital programming ports
primary Standard GPIB connector
IEEE 488.2 (GPIB)
secondary 9 pin D-sub
RS 232 (standard Models only)
secondary RJ 45
LAN (E-Series Models Only)
Feedback/Control Input
5 position low profile Euroblocks
PROGRAMMING CHARACTERISTICS - LOCAL
Local control
rotary encoders
Panel mounted.
Local control resolution
Coarse ~100 LSB/step
Depress control for Fine resolution
Fine 1 LSB/step
Setting range
0-100% of rating
KLP will automatically adjust limit to
maintain 1200 W maximum,
Power up settings
voltage defaults to zero
See PAR. 3.2.9.3.
current defaults to min. value (See Table 1-2)
Protection Limits
Overvoltage 20-120% of Emax
Programmable; accessed via front
panel protect switch or SCPI command
over digital bus.
Overcurrent 72-120% of Imax
TABLE 1-3. KLP SPECIFICATIONS (Continued)
SPECIFICATION
RATING/DESCRIPTION
CONDITION/COMMENT
Содержание KLP 10-150-2
Страница 2: ......
Страница 6: ......
Страница 12: ...vi KLP070312 FIGURE 1 1 KLP SERIES POWER SUPPLY...
Страница 19: ...KLP 070312 1 7 FIGURE 1 3 KLP SERIES POWER SUPPLY MECHANICAL OUTLINE DRAWING SHEET 1 OF 2...
Страница 20: ...1 8 KLP 070312 FIGURE 1 3 KLP SERIES POWER SUPPLY MECHANICAL OUTLINE DRAWING SHEET 2 OF 2...
Страница 27: ...KLP HV 070312 2 3 FIGURE 2 2 KLP SERIES REAR PANEL SWITCH AND CONNECTORS...
Страница 40: ......
Страница 78: ......
Страница 90: ......