KLP070312
3-3
NOTE: A minimum programmed current is required to ensure proper operation of the power
supply under all load conditions. Programmed current is automatically set to be at least
the minimum current (actual value depends on model, see Table 1-2).
• Since the output is off, Constant Voltage (
CV
) mode indicator (green LED) and Con-
stant Current (
CC
) indicator (amber LED) are off.
3.2.2
SETTING LOCAL/REMOTE MODE
LOCAL MODE. When the power supply is turned on, it is automatically set to Local mode as
long as Analog I/O port pin 12 is not grounded. In local mode the Status display is normally
blank.
DIGITAL REMOTE MODE. The power supply will automatically go into digital remote mode
when digital remote commands are accepted via the GPIB, RS 232, or LAN ports. In digital
remote mode the power supply normally shows
dRem
in the status display. The LAN indicator
[E-Series models only] is on when a valid IP address has been found. When in digital remote
mode, all front panel controls are disabled. If desired, local mode can be restored by pressing
both
VOLTAGE
and
CURRENT
controls simultaneously; the power supply will then remain in
local mode until another digital command is received, causing the unit to return to remote digital
mode. The OPERATE INSTRUMENT web page [E-Series models only] must not be active
when restoring local mode. To disable local mode entirely, see PAR. 3.2.2.1 for front panel lock-
out.
NOTE: During both LOCAL and DIGITAL REMOTE operation, the analog readback signals
(voltage and current) remain available, as does the remote inhibit signal; only program-
ming signals are disregarded.
ANALOG REMOTE: With power supply turned off, ground Analog I/O port pin 12. Refer to PAR.
2.7.9 to configure the Analog I/O Port; refer to Table 2-2 to configure the Analog I/O switch.
When the power supply is turned on, the status display shows
aRem
(Analog Remote program-
ming selected). The unit will accept Analog Remote commands (see PAR. 3.4) and front panel
controls are disabled, except that the
DC OUTPUT
ON/OFF
switch is operational. Local mode
can be restored by pressing the
VOLTAGE
and
CURRENT
controls at the same time. Once
local mode has been restored, analog remote programming is disabled until the unit is powered
off, then on again.
NOTE
While Analog Remote programming is active, the unit will respond to digital queries,
but will not respond to most digital commands, except for the front panel unlock com-
mand (see PAR. 3.2.2.1). Note that digital commands that conflict with the analog pro-
gramming settings must not be issued, as these can cause momentary unpredictability
at the output until analog control is reasserted.
Содержание KLP 10-150-2
Страница 2: ......
Страница 6: ......
Страница 12: ...vi KLP070312 FIGURE 1 1 KLP SERIES POWER SUPPLY...
Страница 19: ...KLP 070312 1 7 FIGURE 1 3 KLP SERIES POWER SUPPLY MECHANICAL OUTLINE DRAWING SHEET 1 OF 2...
Страница 20: ...1 8 KLP 070312 FIGURE 1 3 KLP SERIES POWER SUPPLY MECHANICAL OUTLINE DRAWING SHEET 2 OF 2...
Страница 27: ...KLP HV 070312 2 3 FIGURE 2 2 KLP SERIES REAR PANEL SWITCH AND CONNECTORS...
Страница 40: ......
Страница 78: ......
Страница 90: ......