TABLE 1-3. KLP SPECIFICATIONS
SPECIFICATION
RATING/DESCRIPTION
CONDITION/COMMENT
INPUT CHARACTERISTICS
a-c voltage
nominal
100-240 Va-c
Single Phase.
range
90-265 Va-c
Wide Range; contact factory for opera-
tion to 265V a-c.
d-c voltage
range
125-275 Vd-c
No regulatory agency approval.
Frequency
nominal range
50-60 Hz
maximum
45-440 Hz
Increased Leakage above 66 Hz.
Power Factor
typical
0.99
Meets EN 61000-3-2.
Maximum Input Current
120 Va-c
13A rms
Rated load (1200W).
240 Va-c
6.5A rms
Rated load (1200W).
Inrush Current
265 Va-c
40A
Peak
132 Va-c
20A
Peak
Input Fusing
Circuit Breaker
2-line
Low a-c Protection
Self protected
No fixed limits.
Output hold up
typical
10 milliseconds
Ride through.
Leakage Current
115 Va-c, 60Hz
1.2mA max
230 Va-c 50Hz
2.3mA max
Electromagnetic
compatibility
Emissions
CISPR11, Class A
Class B Conducted
Immunity
EN 61326-1, Table 2
Industrial Environment
OUTPUT CHARACTERISTICS
Type of stabilizer
CV/CC
Voltage/Current
Adjustment range
voltage
0-100% of rated voltage
No minimum load required.
current
minimum to 100% of rated current
No minimum load required. See Table
1-2 for minimum programmable current.
Source effect
voltage
0.01% Emax
Over full source range.
current
0.01% Imax
Load effect
voltage
0.01% Emax
Over full load current range.
current
0.02% Imax
(1)(2)
Temperature effect
voltage
0.02%/deg C
0-50 deg C
current
0.05%/deg C
Time effect (drift)
voltage
0.05%/24hr
After 30 min warmup.
current
0.05%/24hr
Error sensing
0.25 volts per wire
Above rated output. Contact factory for
larger margins.
Isolation voltage
600 Vd-c or peak
Either output terminal to ground.
Transient recovery
for load change
excursion
1% of Emax
50% load step 2A/microsecond max.
recovery
2 msec
Return to 0.1% of setting.
Turnon/turnoff overshoot
same as load transient response limits
Overvoltage protection
voltage
20-120% of Emax
Programmable; see PAR. 3.2.16.3.2.
Overcurrent protection
current
72-120% of Imax
Programmable; see PAR. 3.2.16.3.2.
Overtemperature protection
Shutdown
See PAR. 3.2.16.3.2.
Open Load wire protection
Shutdown
See PAR. 3.2.16.3.2.
Parallel operation
Active load sharing within 5% of Io rated Up to 5 units, maximum.
(1) For 20V model: 0.05%. (2) For 600V model: 0.02% + 3.3µA/V of compliance voltage.
Содержание KLP 10-150-2
Страница 2: ......
Страница 6: ......
Страница 12: ...vi KLP070312 FIGURE 1 1 KLP SERIES POWER SUPPLY...
Страница 19: ...KLP 070312 1 7 FIGURE 1 3 KLP SERIES POWER SUPPLY MECHANICAL OUTLINE DRAWING SHEET 1 OF 2...
Страница 20: ...1 8 KLP 070312 FIGURE 1 3 KLP SERIES POWER SUPPLY MECHANICAL OUTLINE DRAWING SHEET 2 OF 2...
Страница 27: ...KLP HV 070312 2 3 FIGURE 2 2 KLP SERIES REAR PANEL SWITCH AND CONNECTORS...
Страница 40: ......
Страница 78: ......
Страница 90: ......