KE-2050/KE-2060, KE-2050R/2055R/KE-2060R Maintenance
Manual
12-9
d
Adjusting the feeder float sensor outside the machine
(1) Turn the volume on the light emission side counterclockwise to the minimum position to put the
sensor in the shut-down state.
(2) Gradually turn the volume clockwise toward the maximum position and stop turning when both
the red and green lamps on the light receiving side are lit.
(3)
et the bulk feeder at the left, center, and right positions of the bank to check that the sensor is
t turned OFF.
S
no
If the sensor is turned ON (green lamp does not light up correctly), turn the volume to
make the green lamp lit.
(4) Set the NF32 feeder at the same positions as described in step (3) and open the top cover by
hand to check that the sensor is turned OFF when the top cover is raised 10 mm or less.
Raise the cover by hand.
If the volume is turned excessively in step (3), the sensor does not respond even
though the cover of the NF32 feeder is opened.
NF32 feeder
(5) Set the NF16 feeder at the same positions as described in step (3) and open the top cover
using the lever to check that the sensor is turned OFF.
Top cover
Lever
If the sensor is not turned OFF, move the sensor mounting position back and forth to
adjust the light-axis, and perform the adjustment again from step (1).
N16 feeder
Rev. 2.00