KE-2050/KE-2060, KE-2050R/2055R/KE-2060R Maintenance Manual
14-68
14-11. Replacing the Fuse of the AC Input Unit
(Note) Before replacing the fuse, always turn OFF the power to the machine, which
becomes the main power supply.
AC input unit
Figure 14-11-1 View when Viewed
from Rear of Machine
1
2
If the fuse in the AC input unit is blown up, follow the
steps below to replace the fuse.
Fuse part No.: HF0110025S0
(Time lag fuse, 250mA Three fuses are supplied with
the machine as accessory parts.)
1.
Take out the AC input unit.
(The AC input unit is located at the position
shown in Figure 14-11-1.)
(Work Procedure)
c
Remove the center cover.
d
Disconnect the UPS cables from the power
supply unit and take out the UPS.
e
Disconnect the cables and take out the AC
input unit.
2. Replace the fuse with a new one. The fuse is mounted at the location shown in Figure
14-11-2.
Fuse
Figure 14-11-2 Top View of AC Input Unit
3.
Mount the AC input unit on the machine in the reverse order of work steps described in step 1.