5-5. Replacing the IN and OUT Sensors
Bind the cables A and B with binding bands, taking care that they are not pulled or loosened
excessively during adjustment of sensor position.
②
③
①
⑤
④
B
A
Figure 5-5-1
40002208 IN_SENS_ASM
40002210 OUT_SENS_ASM
SL4031291SC SCREW
EA9500B0000 CABLE_BAND
<Adjusting the sensitivity>
Make an adjustment so that a (matte) black glass epoxy PWB placed on the transport path can be
detected. Place a (matte) black glass epoxy PWB under the sensor and rotate the sensitivity
adjustment knob of the sensor counterclockwise. Then gradually rotate it clockwise up to the
position at which the specified PWB is detected.
☯
If the black glass epoxy PWB is not available, use the darkest PWB of those to be used.
②
①
④
⑤
③
A
B
Right-side sensor
Left
-side sensor