KE-2050/KE-2060, KE-2050R/2055R/KE-2060R Maintenance
Manual
7-3
(5) Adjust the sensor dog position
When opened:
With the slide plate open, the cylinder should move 0.5 mm to the left after
the OPEN sensor is turned ON.
When closed:
With the slide plate closed, the cylinder should move 0.5 mm to the right
after the CLOSE sensor is turned ON.
Note 1)
After the position has been adjusted, tighten the hexagon socket head bolt with a
nut.
Note 2)
The nut must be tightened with a torque of 1.3N
⋅
m.
Rev. 2.00
Hexagon socket
head bolt
OPEN sensor
Nut
ナ ト
CLOSE sensor
Figure 7-1-3 Adjustment of the Sensor Dog (Hexagon Socket Head Bolt)
Figure 7-1-4 When Opened (Left)/When Closed (Right)
(7) Connect
a
φ
4 air tube.
Refer to the figure below, and connect the speed controller to the solenoid valve with an air
tube (
φ
4).
A
A
B
B
Figure 7-1-5 Air Tube Piping