KE-2050/KE-2060, KE-2050R/2055R/KE-2060R Maintenance
Manual
12-5
(3) Adjust the height of a newly mounted sensor.
c
FSD bracket (feeder float sensor)
Adjust the height of the top surface of the FSD bracket to 127.5 mm from the top surface
of the feeder bank, and secure it.
+
0.3
−
0.0
However, adjust the height of the FSD bracket with a set of left and right sensors (light
receiving and light emission) so that a difference in height is 0.1 mm or less.
Rev. 2.00
FSD spacer
127.5
FSD bracket
Top surface of bank
+0.3
0
Feeder float sensor