DANGER
To prevent any trouble caused by accidental machine start, always
shut-down the power before starting the maintenance and
adjustment work.
[6] CAL
BLOCK
6-1. Replacing the CAL Block Board Assembly
(1) Disconnect two bounded cables
c
from the board.
(2) Disconnect the air tube
d
from the elbow union.
(3) Remove the four M3 SEMS bolts
e
, pull the board downward from the CAL side cover, and
remove it from the
φ
4 air tube. The CAL block board assembly can then be detached.
(4) After the board has been replaced, reassemble the components in the reverse order.
c
d
e
f
When replacing the filter
f
, it is not necessary to turn off the air.
Part No.: 40000641
Part name: Filter