4-5. Adjusting the Focus
<Procedure>
c
lace the camera adjustment jig on the top surface of the calibration block, facing its etching
surface down.
d
Loosen the hexagon socket head cap bolts
c
and
d
(total of 6 locations) that secure the
camera, move the camera up and down, and
when lines up to 2 on the etching surface are
clearly visible (see the figure below), secure
the camera in position.
When the polarizing filter is adjusted to the
scale
“
0
”
(dark) position, the line can be seen
easily. After the adjustment has been
completed, return the polarizing filter to the
scale
“
5
”
(bright) position.
4-6
Rev. 2.10
カメラアジャスト治具
E2106998000
(T110)
The lines around "2" shall be seen clearly.
CALブロック
Calibration block
②座金付六角穴付ボルト
SL6030892TN
(×2)
①座金付六角穴付ボルト
SL6030692TN
(×4)
OCCカメラアッセンブリ
40001212
d
Washer assembled
hexagon socket head
cap bolt
SL6030892 (
×
2)
Camera adjustment jig
E2106998000 (T110)
c
Washer assembled
hexagon socket head
cap bolt
SL6030692 (
×
4)
OCC camera assembly