KE-2050/KE-2060, KE-2050R/2055R/KE-2060R Maintenance Manual
2-16
2-4. Replacing the Laser Sensor
2-4-1. Replacing the MNLA
After the MNLA has been replaced, it is absolutely necessary to re-input the MS parameters related
to the laser. (See section 2-9.)
After the laser sensor has been replaced, wipe the laser window on the MNLA with clean wastes,
etc.
(1) Remove the connector and the mounting screws
20
(3 locations) to detach the MNLA.
(2)
Before mounting the components, remove Loctite sticking to the sensor bracket as
much as possible.
Reassemble the components in the reverse order of disassembly.
Stick flock paper to the bottom surface of the attached sensor after degreasing the
surface.
When attaching the sensor, insert the sensor pin into the positioning hole of the bracket
first. Then fix the sensor.
Apply Loctite 242 to the sensor mounting screws
20
(3 pcs.) and tighten them with a
tightening torque of 5.1 Nm.
⑳
Figure 2-4-1