KE-2050/KE-2060, KE-2050R/2055R/KE-2060R Maintenance
Manual
12-7
(5) Adjust the volume (only the feeder float sensor).
Adjust the volume after the sensor mounting height, mounting position in the Y-direction
(sensor is secured to the center of the oval hole in the sensor bracket), and light-axis have
been adjusted.
Rev. 2.00
Figure 12-10
<Units and tools to be used for adjustment>
•
NF12 (NF16 or NF24 is also accepted.)
→
Non-lock type
•
NF16N (NF12N or NF24N is also accepted.)
The above units are used for adjustment of the feeder float sensor on the transport
side.
•
NF16 (NF12, NF24, NF12N, NF16N, or NF24N is also accepted.)
•
NF32 feeder (NF323S, NF324S, or NF32FS is also accepted.)
•
Bulk feeder (BF10, BF11, or BF12 is also accepted.)
The above units are used for adjustment of the feeder float sensor outside the
machine.
•
Phillips screwdriver and slotted precision screwdriver
Front
(Transport side)
(Outside of machine)
(Outside of machine)
(Transport side)
Top view of mounter
Figure 12-9
Precision
screwdriver
Volume
Counter-
clockwise
Clockwise
Rear
Light
emission
Light
receiving
Light
receiving
Light
emission
Light
receiving
Light
emission
Light
receiving
Light
emission