KE-2050/KE-2060, KE-2050R/2055R/KE-2060R Maintenance Manual
1-2
(2) Loosen the NM6050001SC, and then SM8053002TP that applies the tension to the timing belt
XM.
(3) Remove the timing belt XB. (See also section 1-1-2.)
(4) Remove the SL6064092TN fixing the XA-pulley bracket assembly, and SL6062092TN fixing
the XA-pulley base to detach the XA-pulley bracket assembly.
(5) Remove the SL6062092TN fixing the motor assembly to detach the X-motor assembly.
(6) Replace the timing belt XM.
(7) Reassemble the components in the reverse order of disassembly.
(8) Adjust the tensions of the timing belts XM and XB. (See also “Adjustment Procedure” on page
1-4.)
X-motor
assembly
XA-pulley
bracket assembly
Timing belt XM
X-frame end
* This figure shows the left side of
the unit when viewed from the
side. (The right side has the
same structure.)
Figure 1-1-1-2
Rev. 2.00