104
Trouble shooting
* = Factory adjusted mod
e
Code C0
Setting the factory-adjusted modes of operation
(
F
5.)
0* =
No action
1 =
Set default values
(state 1 is only shown briefl y)
The selected mode of operation can be transferred to
the permanent memory.
Code C1
Selecting the resolution of unbalance readings in
1 or 5 g (= from 0.05 or 0.25 oz.) increments
0* =
5 g (0.25 oz) increments
1 =
1 g (0.05 oz) increments
The selected mode of operation can be transferred to
the permanent memory.
Code C2
Selecting suppression of minor unbalance
readings
0* =
Suppression off
1 =
Suppression on
The selected mode of operation can be transferred to
the permanent memory.
..
Selecting the defi nition of the imbalance value in steps
from 0.05 or 0.25 oz. (respectively 1 or 5 grams).
0* = 0,25 oz (5 grams) defi nition
1
= 0,05 oz (1 gram) defi nition