Terminal connection capacity (digital inputs and outputs)
Rigid/flexible
0.14 - 1.5mm
2
, AWG 28-16
Flexible with core end sheath without plastic sleeve
0.25 - 1.5mm
2
Flexible with core end sheath with plastic sleeve
0.25 - 0.5mm
2
Tightening torque
0.22 - 0.25Nm
Stripping length
7mm
Digital outputs
2 Digital outputs with a joint earth; semiconductor relay, not short-circuit proof
Supply voltage
20V - 30V DC (SELV or PELV supply)
Switching voltage
max. 60V DC, 30V AC
Switching current
max. 50mAeff AC/DC
Response time (Jasic program)
200ms
Output of voltage dips
20ms
Output of voltage exceedance events
20ms
Pulse output (energy pulse)
max. 20Hz
Cable length
up to 30m unshielded, from 30m shielded
Digital inputs
2 Digital inputs with a joint earth
Maximum counter frequency
20Hz
Response time (Jasic program)
200ms
Input signal present
18V to 28V DC (typical 4mA)
Input signal not present
0 to 5V DC, current less than 0.5mA
Cable length
up to 30m unshielded, from 30m shielded