DIGISPENSE 3009 CONTROLLER MODULE, STYLE B
Page 3-98
29 October, 2019
IVEK Corp. P03R017E
y2
y2,<value2>
Returns the current Motor/Base selection.
y2,<value2>
y2,<value2>
Sets the Motor/Base configuration. (Refer to Table 3.2)
<value2>:
Maximum:
7
Minimum:
0 (default)
CAUTION
The Motor/Base Module number selection in the Setup C screen MUST match the Motor/Base Module
attached to the Controller Module. An incorrect setting could overheat the motor and damage the equipment
and cause a hazardous condition.
y3
y3,<value2>
Returns the current Stop Position.
y3,<value2>
y3,<value2>
Sets the stop position in degrees.
<value2>:
Maximum:
330
Minimum:
0
Default:
90
y4
y4,<value2>
Returns the current Meter Stop mode.
y4,<value2>
y4,<value2>
Sets the meter stop mode.
<value2>:
0 = Stop Position (default)
1 = Immediate
y5
y5,<value2>
Returns the current Stalls per Fault.
y5,<value2>
y5,<value2>
Sets the stalls per fault.
<value2>:
Maximum:
15
Minimum:
1
Default:
4
y11
y11,<value2> Returns the current Initial Rate selection.
y11,<value2>
y11,<value2>
Sets the Initial Rate. (Refer to Table 3.2)
<value2>:
0 = Low
1 = Medium
2 = High (default)
z => SOFTWARE VERSION
z or z0
z0,<value2>
Returns the software version as text.
z1
z1,<value2>
Returns the Current device type (DS3009)
z2
z2,<value2>
Returns the firmware CRC
3.4.10 Warnings
Warnings indicate problems in the command received, or a state of the Motor/Base Module which prohibits immediate
operation. An appropriate command (other than ‘clear faults’) may be required to operate the pump.
1
Command Not Valid
- Response to any unrecognized command.
2
Value Not Valid
- Response to any out of range value.
5
Production Mode is Disabled
- An attempt was made to run in production mode while it is disabled.
8
Serial In Motion Not Enabled
- Serial command sent to begin motion while motion disabled due to serial
command.
(k0)
11 Second Command Character
- A second command character (alphabetic character) was seen in a single
command
(before <CR> character). Entire command is ignored.
15 Descriptor Not Valid
- First numerical value not valid for command letter.
16 Recipe Is Blank
17 Recipe Is Not Blank
18 Motion Is Disable Via Logic
- Serial command sent to begin motion while motion disabled due to logic input.