DIGISPENSE 3009 CONTROLLER MODULE, STYLE B
Page 3-51
29 October, 2019
IVEK Corp. P03R017E
3.4.7.7 Setup B Screen
Keylock/Supervisor
D = Display
P = Push-button Accessible
I/O Test
C = Display/Change
N = Not Accessible/Viewable
Operator
0
SETUP B
<
— status —>
2
AUX OUT 1 = <DISABLED>
3
AUX OUT 2 = <DISABLED>
4
OUTPUT 1 = <READY> PRODUCTION
5
OUTPUT 2 = <STATUS> FAULT
6
OUTPUT 3 =
<
BUSY> DISCHARGE
7
OUTPUT 4 = <STATUS> REFERENCE
8
INPUT CC 1 =
<
DISABLED>
9
INPUT CC 2 = <DISABLED>
10
INPUT 1 = <TRIGGER> PRODUCTION OPS
11
INPUT 2 = <TRIGGER> FLUIDIC OPS
12
INPUT 3 = <TRIGGER> FLT CLEAR & REF
13
INPUT 4 = <DISABLED>
if NOT faulted
14
SETUP A
SETUP C
I/O TEST
15
SCREEN
SCREEN
SCREEN
----- Displays the Controller Module Status ........ D D D
----- Display/change the aux out 1 setting ........... D D C
----- Display/change the aux out 2 setting ........... D D C
----- Display/change the output 1 setting ............ D D C
----- Display/change the output 2 setting ............ D D C
----- Display/change the output 3 setting ............ D D C
----- Display/change the output 4 setting ............ D D C
----- Display/change the input CC 1 setting ........ D D C
----- Display/change the input CC 2 setting ........ D D C
----- Display/change the input 1 setting ............... D D C
----- Display/change the input 2 setting ............... D D C
----- Display/change the input 3 setting ............... D D C
----- Display/change the input 4 setting ............... D D C
The following screens are accessible from
this screen based on the system status.
Setup A ................................................................ P P P
Setup C ................................................................ P P P
I/O Test ................................................................ P P P