3.4.7.2 Prime Screen
Keylock/Supervisor
D = Display
P = Push-button Accessible
I/O Test
C = Display/Change
N = Not Accessible/Viewable
Operator
0
PRIME
<
— status —>
2
3
VOLUME PRIMED =
##,### STROKES
4
5
6
RECIPE = ##
7
PRIME DIRECTION =
FORWARD
8
PRIME VOLUME = ##### STROKES
9
PRIMING RATE = #### RPM
10
11
12
13
if dispense mode
14
*
DISPENSE
SETUP A
CHANGE
GET
15
SCREEN
SCREEN
DIRECTION
RECIPE
OR if disabled production mode
14
SETUP A
CHANGE
GET
15
SCREEN
DIRECTION
RECIPE
OR if NO motor/base selected
14
DISPENSE
SETUP A
SETUP C
GET
15
SCREEN
SCREEN
SCREEN
RECIPE
OR if reference required
14
DISPENSE
SETUP A
REFERENCE
GET
15
SCREEN
SCREEN
RECIPE
OR if direction change disabled
14
DISPENSE
SETUP A
GET
15
SCREEN
SCREEN
RECIPE
OR if get recipe disabled
14
DISPENSE
SETUP A
CHANGE
15
SCREEN
SCREEN
DIRECTION
OR if direction change and get recipe disabled
14
DISPENSE
SETUP A
15
SCREEN
SCREEN
NOTE
* Field 3 will display DISPENSE SCREEN when in
Dispense mode or METER SCREEN when in Meter
mode.
----- Displays the Controller Module Status ........ D D D
----- Displays the volume dispensed during prime D D D
----- Displays the current recipe .......................... D D D
----- Display/change the prime direction ............. D D C
----- Display/change the prime duration .............. D D C
----- Display/change the priming rate .................. D D C
The following screens are accessible from
this screen based on the system status.
Dispense .............................................................. P P P
Change Direction ................................................. D D C
Get Recipe ........................................................... P P P
Meter .................................................................... P P P
Setup A ................................................................ P P P
Setup C ................................................................ P P P