DIGISPENSE 3009 CONTROLLER MODULE, STYLE B
Page 3-86
29 October, 2019
IVEK Corp. P03R017E
3.4.8
Status
The status indicates the operational state of the system. The status is displayed in the upper right hand corner of the
display on the Power-Up, Prime, Bubble Clear, Agitate, Dispense, Drawback, Meter, Meter Mult, Setup A, Auto Trig,
Setup B, Setup C, Encoder, System Info, and Fault screens. The status will be one of the following:
IDLE
No operations are active, pump is selected, motion is not disabled, no operating faults exists
PRIMING
The Prime operation is active.
DISPENSING
A Dispense operation is active.
METERING
A Meter operation is active.
DRAWBACK DWELL The Dispense or Meter operation is currently dwelling before drawback
DRAWBACK
The Dispense or Meter operation is currently performing a drawback
CLEARING FAULT
A fault is being cleared
FAULTED
An operating fault exists
REFERENCING
A Reference operation is active
MOTION STOPPED
All motion has been disabled via either a logic signal or a serial command
NOT CONFIGURED
Motor/Base selection is set to 0
INITIALIZING
The system is initializing upon power-up
PRE-OP DWELL
A pre-operation dwell is occurring during a Production Mode operation
POST-OP DWELL
A post-operation dwell is occurring during a Production Mode operation
AUTOTRIG IDLE
A dwell is occurring between Auto Triggered Dispense operations
ISOLATING
The Isolation portion of an Agitate operation is active
AGITATING
The Agitate portion of an Agitate operation is active
RETURNING
The Return portion of an Agitate operation is active
3.4.9 Rear Panel Interfaces
The rear panel has six interface connectors. These interfaces provide a variety of functions for controlling and
monitoring the Controller Module. The interfaces are CC Triggers, Aux 1 Aux 2, Logic I/O, USB, RS232 and RS485.
3.4.9.1 CC TRIGGERS Connector
The CC TRIGGERS connector provides two configurable input signals (Input CC 1 and input CC2) configurable in the
Setup B screen (see 3.3.7.7). The two inputs can be configured as Disabled or a Trigger, Lock or Link input. Do not
connect an external power source to this connector. The internal power source for this signal is optically isolated from
the internal control electronics (isolated power shared with RS232 Serial Interface). Refer to Table 3.4 for signal
descriptions.
3.4.9.2 AUX1 AUX2 Connector
The AUX1 AUX2 connector provides two configurable output signals (Aux Out 1 and Aux Out 2) configurable in the
Setup B screen (see 3.3.7.7). The two outputs can be configured as Disabled or a Busy, Ready, Status, Success or
Link output. This signal will switch an externally-powered device.. Refer to Table 3.5 for signal descriptions.
Table 3.5 Input 1
– Input 4, Input CC 1 and Input CC 2 Signal Description
Type
Condition
True Function
False Function
<DISABLED>
Ignore.
Ignore.
<TRIGR>
PRODUCTION
Start Dispense, Meter, or Autotrigger
Operation
Stop Meter or Autotrigger Operation.
FLUIDIC
Start Prime, Agitate, Operation
Stop Prime or Agitate Operation
CL FLT & REF
Clear Fault and start Reference Operation Ignore.
<LOCK>
MOTION
Unlock (allow) motion to occur
Lock (prohibit) motion from occurring
FRONT PANEL
Unlock (allow) changes via the front panel
Lock (prohibit) changes via the front
panel.
<LINK>
WITH OUTPUT
Depends on output configuration
Depends on output configuration