DIGISPENSE 3009 CONTROLLER MODULE, STYLE B
Page 3-101
29 October, 2019
IVEK Corp. P03R017E
3. On the Pump Module
NOTE
Make sure the inlet tubing is larger than, or the same size as, the outlet tubing. Start with the reservoir even
with or slightly higher than the Pump Module and the Pump Module even with or slightly higher than the
dispense tip. Adjust as necessary to fit your application.
a. Connect the inlet fitting and tubing
b. Connect the gland inlet fitting and tubing (
*
optional)
c. Connect the outlet fitting and tubing
d. Connect the gland outlet fitting and tubing (
*
optional)
3.4.12.2 Start-up
Switch the 1/0 power switch to the '1' position. The Power Up screen will appear and the Idle indicator will illuminate.
This screen displays the firmware version and allows access to the Prime screen and Dispense or Meter screen. Refer
to Section 3.2.1 for a description of each field.
Go to the Dispense section (3.3.13.4) or Meter section (3.3.13.5) if the system has previously been primed. If not,
follow the instructions in the following section.
NOTE
All controllers are sent in Supervisor Level.
3.4.12.3 Prime
Press the PRIME SCREEN push-button to enter Prime mode.
Position the pump for priming (outlet above or even with the inlet) fill all reservoirs with liquid, and make sure all liquid
lines are connected and secure. Press the START push-button to begin priming.. The system will prime based on the
Priming Rate and Prime Volume settings. Pressing the STOP push-button can stop the priming any time.
NOTE
To determine the correct inlet side, the motor connector must be located as shown in the following photos.
3.4.12.4 Dispense
Press the DISPENSE SCREEN push-button to enter Dispense mode. If the left most push-button is labeled METER
SCREEN, or has no label, go to SETUP A screen and change Production Mode to DISPENSE.
To start dispensing press the START button or supply a trigger to the rear panel. The system will dispense the liquid
amount specified in the Volume setting at the rate specified in the Dispense/Meter Rate setting.
When drawback is used, the Dispense Volume setting specifies the net fluid displaced, the actual forward motion is
the sum of the specified dispense volume and the drawback volume. The Drawback Rate during drawback and the
Drawback Dwell (time between the forward and reverse portions of the cycle) settings are shown on the Drawback
screen.
3.4.12.5 Meter
Press the METER SCREEN push-button to enter Meter mode. If the left most push-button is labeled DISPENSE
SCREEN, or has no label, go to SETUP A screen and change Production Mode to METER.