DIGISPENSE 3009 CONTROLLER MODULE, STYLE B
Page 3-103
29 October, 2019
IVEK Corp. P03R017E
3.8
SPECIFICATIONS
CC TRIG Signal Requirements (Standard):
Accepts mechanical contact closure or solid state switch capable of +5 VDC @ 15mA
(max) Power source in Digispense 3009
DO NOT APPLY VOLTAGE
LOGIC I/O Trigger In Requirements:
+24 VDC @ 20mA (max), Customer power source
LOGIC I/O Output Requirements:
Maximum external voltage: +24 VDC
Maximum current: 20mA
AUX OUT Signal Requirements:
Maximum external voltage: 48 VDC
Maximum current: 250 mA
Motor Speed: 1 to 1500 RPM (max RPM may be limited by Motor/Base selection).
3.9
MODEL NUMBER
The model number provides important information about the specifics of your Controller Module at time of order. Refer
to this number when calling IVEK Technical support. The model number for your Controller Module is located in the
Title Page section of this manual and on the rear of the Controller Module.
520235 -
# #
# #
#
Motor/Base
B
- 1500 RPM 48 VDC @ 5A
Logic Interface
B
- LOGIC I/O, Recipes, Dual CC & Aux.
Communications
B
- RS232, RS485, USB
Front Panel
B
- Membrane Sw, LCD w/LED Bk Lt
Line Cord & Agency Approval
A
- US Cord & CE
B
- International Cord (no plug) & CE
C
- US Cord & CE, NRTL Certified
D
- International Cord (no plug) & CE, NRTL Certified
3.10
ILLUSTRATED PARTS BREAKDOWN
Contact IVEK Corporation Technical Support for information pertaining to replacement parts for this Controller
Module.