DIGISPENSE 3009 CONTROLLER MODULE, STYLE B
Page 3-56
29 October, 2019
IVEK Corp. P03R017E
Setup D Screen Description -
The Setup D screen displays some additional settings for the Controller Module and
allows
a user with Supervisor permission to change the parameters. The current permission level determines which
push-buttons are available as shown.
The Start push-button is not functional, but the Stop push-button is functional while this screen is visible.
RS232/USB Baud Rate -
The RS232/USB Baud Rate determines the number of signals transferred in one second of
the RS232 and USB network. The baud rate can either be 9600, 19200, 38400 or 57600.
RS485 Baud Rate -
The RS485 Baud Rate determines the number of signals transferred in one second of the RS485
network. The baud rate can either be 9600, 19200, 38400 or 57600.
Comm Address -
The Comm Address is the serial address of this Controller Module. The Comm Address can be
between 1 and 99.
Comm Gateway -
The Comm Gateway allows communication between the RS232/USB and RS485 networks. The
Comm Gateway can either be Enabled or Disabled.