DIGISPENSE 3009 CONTROLLER MODULE, STYLE B
Page 3-91
29 October, 2019
IVEK Corp. P03R017E
<value3> Third numerical parameter
This is a read only parameter and all numerical values will be ignored. All values in the command string which are not
required by the command specified will be ignored. Following is an example of a command string.
v0,100<CR>
Command v0(dispense volume), a setting of 100 strokes (non-address mode)
1v0,100<CR>
Command v0(dispense volume), a setting of 100 strokes (address mode, address = 1).
Transmission should stop when an ASCII carriage return character is sent and can resume when the ASCII carriage
return of the response is received.
Response String
The response from the Controller Module has a format which is very similar to the command with the addition of a fault
or warning value.
<name>
Represents an argument
,
Field delimiter character for numerical arguments.
<CR>
End of command represented by ASCII carriage return character (no line feed).
The complete command form is: <address><cmd><value1>,<value2>,<value3><CR>
The description for the response string above follows the structure of the command string previously described except
for value3 which is a warning or fault code. Some responses to errant command strings contain special identifiers in
the <cmd> location.
Commands
The command set controls the overall settings of the system. Tables 3.8 list the commands.
NOTE
Refer to previous description for complete command syntax (“COMMAND STRUCTURE”).
<value3> has been omitted from the response in this table, but will either be a 0 if no faults or warnings exist
or will provide the fault or warning number.
Table 3.8 Commands
Command
Response
Description
a => Autoload
a2
a2,<value2>
Returns current Autotrigger Mode setting.
a2, <value2> a2,<value2>
Autotrigger Mode.
<value2>:
0 = Disabled (default)
1 = Count
2 = Infinite
a3
a3,<value2>
Returns current Autotrigger Count setting.
a3, <value2>
a3,<value2>
Autotrigger Count.
<value2>:
2 = minimum (default)
65535 = maximum
b => BEGIN
b or b0
b0,0
Initiates a Dispense/ Meter pumping cycle.
b1
b1,0
Initiates a Prime/Agitate pumping cycle.