Operation
ORBIMAT CA
| Operating instructions
44
orbitalum tools
GmbH, D-78224 Singen, www.orbitalum.com, Tel. +49 (0) 77 31 792-0
(09.03.15) OW_ORBIMAT_CA_BA_871060202_04_EN
5. Move sector border to the desired position with the rotary knob.
6. Briefly press the rotary knob.
The sector border is saved at the new position. The sector list is updated accordingly.
Adjusting sector borders with the keyboard
1. In the main menu, select "
Manual/Adjust programming
" > "
Adjust parameters
".
2. Select desired sector, e.g "
sector 1
".
3. Select and highlight the "
Final angle
" field, enter a value and save it.
To adjust other sectors:
4. Select"
go forward to sector ...
" or "
go backward to sector …
" final angel of level 1, you select level 1, then choose.
Moving/deleting sectors
Example:
Divide sector 1 (0–90°) into two sectors. New border at 45°.
1. In the main menu, select "
Manual/Adjust programming
" > "
Devide into levels
".
The sector list appears on the left in the display (five sectors in the example, see Fig. 22). The process sequence ap-
pears on the right.
2. Move pointer to the 45° position with the rotary knob.
3. Briefly press the rotary knob.
The new sector border is set, and the sector list is updated. The new sector appears in the list.
The parameters of the new sector are copied from the previous sector.
4. Adjust parameters of the new sector.
Example:
Delete sector 1
1. In the main menu, select "
Manual/Adjust programming
" > "
Devide into levels
".
The sector list appears on the left in the display (five sectors in the example, siehe Fig. 21). The process sequence ap-
pears on the right.
2. Move pointer to the 90° position with the rotary knob.
3. Ensure that the pointer is positioned correctly. For this purpose, compare value in the sector list (end sector 1 = 90°)
with the degree information.
4. Briefly press the rotary knob.
5. Move pointer to the next-lowest border to the left (0°) with the rotary knob.
6. Briefly press the rotary knob.
Sectors 1 (0–90°) and 2 (90–185°) are combined to form a new sector 1 (0–185°). Sector 1 and the parameters of this
sector are deleted. The new sector has the parameters of the old sector 2.
7. Check parameters of the sector.
Note:
Moving the sector border to the right (185°) causes the new sector 1 to accept the parameters of the old sector 1.