ORBIMAT CA
| Operating instructions
Operation
(09.03.15) OW_ORBIMAT_CA_BA_871060202_04_EN
orbitalum tools
GmbH, D-78224 Singen, www.orbitalum.com, Tel. +49 (0) 77 31 792-0
31
8.1.5
Configuring pipe diameter
1. Select "
Diameter
" field.
The following display appears:
2. Select value by pressing the rotary knob.
3. Enter values via the external keyboard or the rotary
knob.
The value range is automatically limited to the possible
diameter range of the connected or previously selected
weld head here.
Fig. 12:
Pipe diameter setting
8.1.6
Configuring wall thickness
1. Select "
Wall thickness
" field and briefly press the rotary knob.
The value range is limited to 4 mm (0.157").
We recommend a "tulip-shaped" or "U-shaped" preparation for wall thicknesses approx. 4 mm (0.157")
and larger, which might require carrying out your own weld tests.
Auto programming can be helpful here, because you can enter the thickness of the bluntly-joined root
face (usually 1.5 - 2.5 mm/0.059" - 0.098") as the wall thickness first, and then manually improve the
auto programmed procedure calculated in this way.
2. Select value by pressing the rotary knob.
3. Enter values via the external keyboard or the rotary knob.
8.1.7
Configuring wire feed
Selection is only possible if the connected weld head is capable of cold wire feeding.
If cold wire feeding is not possible, the option fields are given a gray background, "
No
" is configured and this cannot be
changed by the operator (see also Fig. 12).
1. Select "
Wire feed
" field and briefly press the rotary knob.
2. Select "
Yes
" option (with wire feed) and "
No
" option (without wire feed).
8.1.8
Calculating procedure
X
Select and briefly press the "
Calculate procedure
" menu item.
The procedure is calculated. The main menu appears in the display.