ORBIMAT CA
| Operating instructions
Set-up and assembly
(09.03.15) OW_ORBIMAT_CA_BA_871060202_04_EN
orbitalum tools
GmbH, D-78224 Singen, www.orbitalum.com, Tel. +49 (0) 77 31 792-0
27
3. Navigate to the "
Service
" menu item.
4. Briefly press rotary knob.
The desired selection appears.
Fig. 6:
Sub-menu - System Adjustments
5. Select the "
Pump water out
" menu item.
6. Briefly press rotary knob.
The "
Pumping water out
" message appears.
The "
Cancel
" button is highlighted in blue.
Fig. 7:
Sub-menu - Service
Fig. 8:
Pumping out water
7. Allow water pump to run until the coolant exits the
drain hose under pressure.
8. Confirm "
Cancel
" by briefly pressing the rotary knob.
The water pump is switched off. The water pump is now
filled with coolant and is ready for operation.