Set-up and assembly
ORBIMAT CA
| Operating instructions
24
orbitalum tools
GmbH, D-78224 Singen, www.orbitalum.com, Tel. +49 (0) 77 31 792-0
(09.03.15) OW_ORBIMAT_CA_BA_871060202_04_EN
1. Hook carabiner of the hose assembly for strain relief into the strain relief eye (Fig. 3, Item 7).
2. Insert 24-pin control plug of the weld head into the control line (Fig. 3, Item 6).
3. Insert the two weld current plugs for the ground connection (Fig. 3, Item 5) and the electrode connection (Fig. 3,
Item 4). Ensure that both plugs are inserted fully and are firmly seated.
4. Connect water hoses to the quick-action closures (Fig. 3, Item 3 and Item 2) The direction of flow of the cooling
water is not important here. Ensure that they engage properly and are free of kinks.
5. Insert gas hose with plug-in nipple into gas hose connection (Fig. 3, Item 1).
A dummy plug (Fig. 4, Item 5)
must
be inserted into the remote control connection if remote control will not
be used (standard scope of delivery). The system may only be operated if either the dummy plug is inserted
or a remote control is connected.
6. Insert a dummy plug into the remote control connection (Fig. 4, Item 5) if necessary.
Properly connected weld head:
Fig. 4:
Weld head, connected
7.3.4
Detaching water hoses
X
Lightly push back front ring on machine-side connection and pull off water hose.
7.3.5
Pumping out coolant
The connections of the machine close automatically when the water hose is removed.
X
When connecting the water hoses, pay attention to the flow and return.
1. Connect drain hose to the water connection, blue (Fig. 3, Item 3).
2. Close off the water hoses with the included plugs to prevent the coolant from running out of the weld head.
7.3.6
Closing off gas hose
X
Actuate the side pawl on the hose-side plug connection and pull gas hose out of connection.