List of Function Parameters
130
Function
Code
Name
Description
Factory
Setting
Modify LCD Display
PC.03
Communication
delay time
0~20ms
0
○
COM DELAY
TIME
PC.04
Communication
timeout delay
0.0
(
invalid
)
0.1~100.0s
0.0s
○
COM
TIMEOUT
PC.05
Response action
0: Enabled
1: Disabled
0
○
RESPONSE
ACTION
PC.06
Communication
fault action
0: Alarm and coast to stop
1: Not alarm and keep
running
2: Not alarm and stop if
command source is
communication
3: Not alarm and stop in any
command source
0~3
0
FAULT
ACTION