Detailed Function Description
64
Setting
value
Function
Description
10
Up command
11
DOWN
command
12
Clear
UP/DOWN
The reference frequency of inverter can be adjusted by UP
command and DOWN command.
Use this terminal to clear UP/DOWN setting. Please refer
to description of P0.02.
13
Switch
between A
and B
14
Switch
between A
and A+B
15
Switch
between B
and A+B
P0.06
Terminal action
A B
A+B
13 valid
B
A
14 valid
A+B
A
15 valid
A+B
B
16
Multi-step
speed
reference1
17
Multi-step
speed
reference 2
18
Multi-step
speed
reference 3
19
Multi-step
speed
reference 4
16 steps speed control can be realized by the combination
of these four terminals. For details, please refer to
following multi-step speed reference terminal status and
according step value table:
Such as:
0000: select the multi-speed 0; 1111: multi-speed 15.
Notice: multi-speed 1 is low bit, and multi-speed 4 is high
bit.
Multi-speed
terminal 4
Multi-speed
terminal 3
Multi-speed
terminal 2
Multi-speed
terminal 1
BIT3
BIT2
BIT1
BIT0
20
Multi-step
speed pause
Can shield the function of multi-speed terminals and
keep the set value as the current status.
Содержание CHV Series
Страница 2: ......
Страница 12: ...Introduction 4 1 4 Parts Description Figure 1 2 Parts of inverter 15kw and below...
Страница 13: ...Introduction 5 Figure 1 3 Parts of inverters 18 5KW and above...
Страница 23: ...Disassemble and Installation 15 Figure 3 7 Disassembly of metal plate cover Figure 3 8 Open inverter cabinet...
Страница 25: ...Wiring 17 4 1 Connections of Peripheral Devices Figure 4 1 Connections of peripheral devices...