Detailed Function Description
73
Setting
Value
Function
Range
0
Running frequency
0~maximum frequency (P0.07)
1
Reference frequency
0~ maximum frequency (P0.07)
2
Motor speed
0~2* rated synchronous speed of motor
3
Output current
0~2* inverter rated current
4
Output voltage
0~2* inverter rated voltage
5
Output power
0~2* rated power
6
Output torque
0~2*rated torque
7 AI1
voltage
0~10V
8 AI2
voltage/current
0~10V/0~20mA
9 AI3
voltage
-10V~10V
10 AI4
voltage
0~10V
11 HDI1
frequency
0.1~50.0kHz
12 HDI2
frequency
0.1~50.0kHz
13
Length value
0~preset length (P8.19)
14
Count value
0~preset count value (P8.22)
Function
Code
Name
Description
Setting
Range
Factory
Setting
P6.10
AO1 lower limit
0.0%~100.0%
0.0~100.0
0.0%
P6.11
AO1 lower limit
corresponding output
0.00V ~10.00V
0.00~10.00
0.00V
P6.12
AO1 upper limit
0.0%~100.0%
0.0~100.0
100.0%
P6.13
AO1 upper limit
corresponding output
0.00V ~10.00V
0.00~10.00
10.00V
P6.14
AO2 lower limit
0.0%~100.0%
0.0~100.0
0.0%
P6.15
AO2 lower limit
corresponding output
0.00V ~10.00V
0.00~10.00
0.00V
P6.16
AO2 upper limit
0.0%~100.0%
0.0~100.0
100.0%
P6.17
AO2 upper limit
corresponding output
0.00V ~10.00V
0.00~10.00
10.00V
Содержание CHV Series
Страница 2: ......
Страница 12: ...Introduction 4 1 4 Parts Description Figure 1 2 Parts of inverter 15kw and below...
Страница 13: ...Introduction 5 Figure 1 3 Parts of inverters 18 5KW and above...
Страница 23: ...Disassemble and Installation 15 Figure 3 7 Disassembly of metal plate cover Figure 3 8 Open inverter cabinet...
Страница 25: ...Wiring 17 4 1 Connections of Peripheral Devices Figure 4 1 Connections of peripheral devices...