Detailed Function Description
95
Terminal
Step
Multi-step
speed
reference1
Multi-step
speed
reference2
Multi-step
speed
reference3
Multi-step
speed
reference4
0 OFF OFF OFF OFF
1 ON OFF OFF OFF
2 OFF ON OFF OFF
3 ON ON OFF OFF
4 OFF OFF ON OFF
5 ON OFF ON OFF
6 OFF ON ON OFF
7 ON ON ON OFF
8 OFF OFF OFF ON
9 ON OFF OFF ON
10 OFF ON OFF ON
11 ON ON OFF ON
12 OFF OFF ON ON
13 ON OFF ON ON
14 OFF ON ON ON
15 ON ON ON ON
Function
Code
Name
Description
Setting
Range
Factory
Setting
PA.34
ACC/DEC time selection for step
0~7
0~65535 0~65535
0
PA.35
ACC/DEC time selection for step
8~15
0~65535 0~65535
0
These parameters are used to determine the ACC/DEC time from one step to next step.
There are four ACC/DEC time groups.
Function
Code
Binary Digit
Step
No.
ACC/DEC
Time 0
ACC/DEC
Time 1
ACC/DEC
Time 2
ACC/DEC
Time 3
BIT1
BIT0
0 00 01 10 11
BIT3
BIT2
1 00 01 10 11
BIT5
BIT4
2 00 01 10 11
BIT7
BIT6
3 00 01 10 11
BIT9
BIT8
4 00 01 10 11
BIT11
BIT10
5 00 01 10 11
BIT3
BIT12
6 00 01 10 11
PA.34
BIT15
BIT14
7 00 01 10 11
Содержание CHV Series
Страница 2: ......
Страница 12: ...Introduction 4 1 4 Parts Description Figure 1 2 Parts of inverter 15kw and below...
Страница 13: ...Introduction 5 Figure 1 3 Parts of inverters 18 5KW and above...
Страница 23: ...Disassemble and Installation 15 Figure 3 7 Disassembly of metal plate cover Figure 3 8 Open inverter cabinet...
Страница 25: ...Wiring 17 4 1 Connections of Peripheral Devices Figure 4 1 Connections of peripheral devices...