Detailed Function Description
55
Function
Code
Name
Description
Setting Range
Factory
Setting
P2.01
Motor rated
frequency
0.01Hz~P0.07 0.01~P0.07 50.00Hz
P2.02
Motor rated
speed
0~36000rpm 0~36000 1460rpm
P2.03
Motor rated
voltage
0~3000V 0~3000
Depend on
model
P2.04
Motor rated
current
0.1~2000.0A 0.1~2000.0
Depend on
model
P2.05
Motor rated
power
1.5~900.0kW 1.5~900.0
Depend on
model
Notice:
z
In order to achieve superior performance, please set these parameters
according to motor nameplate, then perform autotuning.
z
The power rating of inverter should match the motor. If the bias is too
big, the control performances of inverter will be deteriorated distinctly.
z
Reset P2.05 can initialize P2.06~P2.10 automatically.
Function
Code
Name
Description
Setting Range
Factory Setting
P2.06
Motor stator
resistance
0.001~65.535
Ω
0.001~65.535
Depend on model
P2.07
Motor rotor
resistance
0.001~65.535
Ω
0.001~65.535
Depend on model
P2.08
Motor leakage
inductance
0.1~6553.5mH
0.1~6553.5
Depend on model l
P2.09
Motor mutual
inductance
0.1~6553.5mH
0.1~6553.5
Depend on model
P2.10
Current
without load
0.01~655.35A
0.01~655.35
Depend on model
After autotuning, the value of P2.06~P2.10 will be automatically updated.
Notice: Do not change these parameters, otherwise it may deteriorate the control
performance of inverter.
Содержание CHV Series
Страница 2: ......
Страница 12: ...Introduction 4 1 4 Parts Description Figure 1 2 Parts of inverter 15kw and below...
Страница 13: ...Introduction 5 Figure 1 3 Parts of inverters 18 5KW and above...
Страница 23: ...Disassemble and Installation 15 Figure 3 7 Disassembly of metal plate cover Figure 3 8 Open inverter cabinet...
Страница 25: ...Wiring 17 4 1 Connections of Peripheral Devices Figure 4 1 Connections of peripheral devices...