DC braking time: The time used to perform DC braking. If the time is 0, the DC braking
will be invalid.
Figure 6.6 DC braking diagram.
Function
Code
Name
Description
Setting Range
Factory
Setting
P1.13
Dead time of
FWD/REV
0.0~3600.0s 0.0~3600.0 0.0s
Set the hold time at zero frequency in the transition between forward and reverse
running.
It is shown as following figure:
Figure 6.7 FWD/REV dead time diagram.