Detailed Function Description
77
P7.06 defines the parameters that can be displayed by LED in running status. If Bit is 0,
the parameter will not be displayed; If Bit is 1, the parameter will be displayed. Press
》
/SHIFT to scroll through these parameters in right order . Press DATA/ENT +
QUICK/JOG to scroll through these parameters in left order.
The display content corresponding to each bit of P7.06 is described in the following
table:
BIT7
BIT6
BIT5
BIT4
BIT3
BIT2
BIT1
BIT0
AI1
Output
terminal
status
Input
terminal
status
PID
feedback
PID
preset
Output
torque
Output
power
Rotation
speed
BIT15
BIT14
BIT13
BIT12
BIT11
BIT10
BIT9
BIT8
Count
value
Length
value
Step No.
of PLC or
multi-step
HDI2
frequency
HDI1
frequency
AI4 AI3 AI2
For example, if user wants to display rotation speed, output power, output torque, PID
preset and AI1, the value of each bit is as the following table:
BIT7
BIT6
BIT5
BIT4
BIT3
BIT2
BIT1
BIT0
1 0 0 0 1 1 1 1
BIT15
BIT14
BIT13
BIT12
BIT11
BIT10
BIT9
BIT8
0
0
0 0 0 0 0 0
The value of P7.06 is 008Fh.
Notice: I/O terminal status is displayed in decimal.
For details, please refer to
description of P7.19 and P7.20.
Function
Code
Name
Description
Setting
Range
Factory
Setting
P7.07
Stop status display
selection
1~0xFFFF 1~0xFFFF
0x00FF
P7.07 determines the display parameters in stop status. The setting method is similar
with P7.06.
The display content corresponding to each bit of P7.07 is described in the following
table:
Содержание CHV Series
Страница 2: ......
Страница 12: ...Introduction 4 1 4 Parts Description Figure 1 2 Parts of inverter 15kw and below...
Страница 13: ...Introduction 5 Figure 1 3 Parts of inverters 18 5KW and above...
Страница 23: ...Disassemble and Installation 15 Figure 3 7 Disassembly of metal plate cover Figure 3 8 Open inverter cabinet...
Страница 25: ...Wiring 17 4 1 Connections of Peripheral Devices Figure 4 1 Connections of peripheral devices...