Heatsink Clip Load Metrology
Thermal and Mechanical Design Guidelines
81
Appendix B
Heatsink Clip Load
Metrology
B.1
Overview
This section describes a procedure for measuring the load applied by the
heatsink/clip/fastener assembly on a processor package.
This procedure is recommended to verify the preload is within the design target range
for a design, and in different situations. For example:
•
Heatsink preload for the LGA775 socket
•
Quantify preload degradation under bake conditions.
Note:
This document reflects the current metrology used by Intel. Intel is continuously
exploring new ways to improve metrology. Updates will be provided later as this
document is revised as appropriate.
B.2
Test Preparation
B.2.1
Heatsink Preparation
Three load cells are assembled into the base of the heatsink under test, in the area
interfacing with the processor Integrated Heat Spreader (IHS), using load cells
equivalent to those listed in Section
To install the load cells, machine a pocket in the heatsink base, as shown in
Figure
7-9. The load cells should be distributed evenly, as close as
possible to the pocket walls. Apply wax around the circumference of each load cell and
the surface of the pocket around each cell to maintain the load cells in place during
the heatsink installation on the processor and motherboard (Refer to Figure
The depth of the pocket depends on the height of the load cell used for the test. It is
necessary that the load cells protrude out of the heatsink base. However, this
protrusion should be kept minimal, as it will create additional load by artificially
raising the heatsink base. The measurement offset depends on the whole assembly
stiffness (i.e. motherboard, clip, fastener, etc.). For example, the reference design clip
and fasteners assembly stiffness is around 380 N/mm [2180 lb/in]. In that case, a
protrusion of 0.038 mm [0.0015”] will create an extra load of 15 N [3.3 lb].
Figure
7-10 shows an example using the reference design.
Note:
When optimizing the heatsink pocket depth, the variation of the load cell height
should also be taken into account to make sure that all load cells protrude equally
from the heatsink base. It may be useful to screen the load cells prior to installation to
minimize variation.
Содержание Celeron Dual-Core E1000 Series
Страница 10: ...10 Thermal and Mechanical Design Guidelines...
Страница 26: ...Processor Thermal Mechanical Information 26 Thermal and Mechanical Design Guidelines...
Страница 68: ...ATX Thermal Mechanical Design Information 68 Thermal and Mechanical Design Guidelines...
Страница 86: ...Heatsink Clip Load Metrology 86 Thermal and Mechanical Design Guidelines...
Страница 88: ...Thermal Interface Management 88 Thermal and Mechanical Design Guidelines...
Страница 120: ...Legacy Fan Speed Control 120 Thermal and Mechanical Design Guidelines...
Страница 124: ...Balanced Technology Extended BTX System Thermal Considerations 124 Thermal and Mechanical Design Guidelines...
Страница 126: ...Fan Performance for Reference Design 126 Thermal and Mechanical Design Guidelines...
Страница 127: ...Fan Performance for Reference Design Thermal and Mechanical Design Guidelines 127...
Страница 139: ...Mechanical Drawings Thermal and Mechanical Design Guidelines 139 Figure 7 57 Reference Fastener Sheet 1...
Страница 140: ...Mechanical Drawings 140 Thermal and Mechanical Design Guidelines Figure 7 58 Reference Fastener Sheet 2...
Страница 141: ...Mechanical Drawings Thermal and Mechanical Design Guidelines 141 Figure 7 59 Reference Fastener Sheet 3...
Страница 142: ...Mechanical Drawings 142 Thermal and Mechanical Design Guidelines Figure 7 60 Reference Fastener Sheet 4...