must be pressed before a code is entered to set Area
“
A
”
Monitor Mode. If a keypad is assigned to
both Partitions, this option should be set to allow individual arming of Monitor Mode for each area.
Option 3
“
CODE
”
required to set
- If this option is set, the
“
ARM
”
button is disabled and the panel requires a
code to arm as well as disarm.
Option 4
“
ARM
”
button can disarm during exit delay
- If this option is on then the
“
arm
”
button can disarm
Partition
“
A
”
during the exit delay time with a single press of the button. If the option is off then the
alarm can only be unset by a valid code, even during the exit delay time.
Option 5
“
MONITOR
”
button can disarm Monitor Mode
- This option allows the
“
Monitor
”
button to disarm
monitor mode at any time (including when Monitor Mode is fully set). If the option is off then Monitor
Mode can only be unset by a valid code. This feature is defaulted to keypad addresses 1 & 4 ( 4
being the default address for the monitor key station).
Option 6
No Exit Beeps to keypads in Monitor Mode -
This option stops the exit beeps from occurring at all
keypads when Monitor Mode is set. Normally used for silent night arming.
Option 7
Enable Partition
“
A
”
Key-switch -
If this option is turned on then the system tamper input (Tmp)
becomes a Dual End of Line Input (Refer to Type 4 drawing on Page 5 for wiring details). The low
input 4K7 is reserved for Partition
“
A
”
key-switch operation. An open circuit will still be seen as a
system tamper.
Option 8
Key-switch Mode -
If this option is On then the key-switch has a toggle function (ie the arm/disarm
state will follow the key-switch state). If Off then the key-switch is momentary (ie each single pulse
will change the arm/disarm state). The panel tamper input is used to provide the key-switch function.
PARTITION
“
A
”
OUTPUT OPTIONS
PARTITION
“
A
”
OUTPUT OPTIONS - P111E - P118E
This block of addresses sets a number of output options which are specific and unique to the operation of partition
or Area "A". Activity in Areas "B" will have no direct effect on the options set at these addresses.
P111E
1E
Arm status to output- Default off
2E
Monitor Mode on status to output- Default off
3E
Disarm status to output- Default off
4E
Pendant chirps for Arm to output - Default off
5E
Pendant chirps for Monitor Mode On to output - Default off
6E
Pendant chirps for Disarm to output - Default off
7E
Pulse on Arming to output - Default off
8E
Pulse on Disarming to output - Default off
Option 1
Arm indication to output
- This option will turn the output on when Area "A" is armed. The output
will turn on at the start of the exit delay and turn off when the Area is disarmed. The output reset time
should be set to zero.
Option 2
Monitor Mode On indication to output
- This option will turn the output on when Area "A" Monitor
Mode is armed. The output will turn on at the start of the exit delay and turn off when Monitor Mode is
disarmed. The output reset time should be set to zero.
Option 3
Disarm indication to output
- This option will turn the output on when Area "A" is Disarmed. The
output will turn on when the Area
“
A
”
is disarmed and turn off when the Area is Armed or in Monitor
Mode. The output reset time should be set to zero.
Option 4
Pendant Chirps for Arm to output
- This option will map two short pulses (Chirps) to the output
when Area "A" is armed via a radio key (Pendant) ,( the length of the pulses is set by the pulse timer
P221E-P228E).
Option 5
Pendant Chirps for Monitor Mode On to output
- This option will map two short pulses (Chirps) to
the output when Area "A" Monitor Mode is set via a radio key (Pendant) ,( the length of the pulses is
set by the pulse timer P221E-P228E).