MAPPING ZONE TAMPERS TO OUTPUTS
ZONE TAMPER MAPPING TO OUTPUTS - P91E - P98E
When a zone input is set for Dual-End-of-Line (P130E) the short & open circuit tampers are
automatically enabled for that zone input. This option allows the zone tamper alarms to be mapped
through to individual outputs. A zone tamper 1-4 is a short on the input and a zone tamper 5-8 is an
open loop.
P91E
Zone Tamper to Output #1. Options= Zone Tampers 1-8 (Default=1-8)
P92E
Zone Tamper to Output #2. Options= Zone Tampers 1-8 (Default=1-8)
P93E
Zone Tamper to Output #3. Options= Zone Tampers 1-8 (Default=1-8)
P94E
Zone Tamper to Output #4. Options= Zone Tampers 1-8 (Default=1-8)
P95E
Zone Tamper to Output #5. Options= Zone Tampers 1-8 (Default=1-8)
P96E
Zone Tamper to Output #6. Options= Zone Tampers 1-8 (Default=1-8)
P97E
Zone Tamper to Output #7. Options= Zone Tampers 1-8 (Default=1-8)
P98E
Zone Tamper to Output #8. Options= Zone Tampers 1-8 (Default=1-8)
MAPPING RADIO KEYS TO OUTPUTS
RADIO KEY(PENDANT) MAPPING TO OUTPUTS - P101E - P108E
When a Radio Key is to be used to operate a garage door or similar function this block of addresses
allows individual Radio Keys to be mapped to selected outputs. The default setting is that none of the
8 Radio Keys are mapped to any outputs.
P101E
Radio Key to Output #1. Options=Pendant 1-8 (Default=None)
P102E
Radio Key to Output #2. Options=Pendant 1-8 (Default=None)
P103E
Radio Key to Output #3. Options=Pendant 1-8 (Default=None)
P104E
Radio Key to Output #4. Options=Pendant 1-8 (Default=None)
P105E
Radio Key to Output #5. Options=Pendant 1-8 (Default=None)
P106E
Radio Key to Output #6. Options=Pendant 1-8 (Default=None)
P107E
Radio Key to Output #7. Options=Pendant 1-8 (Default=None)
P108E
Radio Key to Output #8. Options=Pendant 1-8 (Default=None)
TEMPORARY OUTPUT DISABLE
This address P109E allows a technician to select any output/s to be temporarily disabled for one alarm or armed
cycle, eg by turning on LEDS 1-4 at P109E then leaving program mode, outputs 1-4 will not turn on following any
alarms. The technician is now free to arm the system to test all monitoring signals without having all of the internal
& external alarms activating. When the alarm is reset or disarmed all outputs will now work normally again.
P109E
Select output # 1-8
PARTITION
“
A
”
OPTIONS
PARTITION
“
A
”
OPTIONS - P110E
This address allows modification of how Partition
“
A
”
arming, monitor and control keys work at the keypad.
P110E 1E
“
ARM
”
button required before code to set- Default off
2E
“
MONITOR
”
button required before code to turn on Monitor Mode- Default off
3E
“
CODE
”
required to arm- Default off
4E
“
ARM
”
button can disarm system during exit delay- Default on
5E
“
MONITOR
”
button can disarm Monitor Mode at any time- Default on
6E
No Exit Beeps to keypads in Monitor Mode- Default off
7E
Key-switch Enabled- Default off
8E
Key-switch Mode- Default off
Option 1
“
ARM
”
button required before code to set
- This option determines if the
“
ARM
”
button must be
pressed before a code is entered to set Area
“
A
”
. If a keypad is assigned to both Partitions, this
option should be set to allow individual arming of each area. This option disables the Arm button from
disarming during the exit delay.
Option 2
“
MONITOR
”
button required before code to set
- This option determines if the
“
MONITOR
”
button