Page 16
MAPPING ZONE ALARMS TO OUTPUTS
ZONE ALARM MAPPING TO OUTPUTS - P51E - P58E
When a zone is in alarm (during the ARMED state only) this block of addresses allows individual
zones to be mapped to selected outputs. The default setting is that zones 1-8 will turn on all outputs
1-8 when in alarm.
P51E
Zone Alarms to Output #1. Options=Zones 1-8 (Default=1-8)
P52E
Zone Alarms to Output #2. Options=Zones 1-8 (Default=1-8)
P53E
Zone Alarms to Output #3. Options=Zones 1-8 (Default=1-8)
P54E
Zone Alarms to Output #4. Options=Zones 1-8 (Default=1-8)
P55E
Zone Alarms to Output #5. Options=Zones 1-8 (Default=1-8)
P56E
Zone Alarms to Output #6. Options=Zones 1-8 (Default=1-8)
P57E
Zone Alarms to Output #7. Options=Zones 1-8 (Default=1-8)
P58E
Zone Alarms to Output #8. Options=Zones 1-8 (Default=1-8)
MAPPING MONITOR ZONE ALARMS TO OUTPUTS
MONITOR ZONE ALARM MAPPING TO OUTPUTS - P61E - P68E
When a Monitor Mode zone is in alarm (during the MONITOR state only) this block of addresses
allows individual zones to be mapped to selected outputs. The default setting is that zones 1-8 will
turn on output 2 only when a monitor mode alarm occurs.
P61E
Monitor Mode Zone Alarms to Output #1. Options=Zones 1-8 (Default=None)
P62E
Monitor Mode Zone Alarms to Output #2. Options=Zones 1-8 (Default=1-8)
P63E
Monitor Mode Zone Alarms to Output #3. Options=Zones 1-8 (Default=None)
P64E
Monitor Mode Zone Alarms to Output #4. Options=Zones 1-8 (Default=None)
P65E
Monitor Mode Zone Alarms to Output #5. Options=Zones 1-8 (Default=None)
P66E
Monitor Mode Zone Alarms to Output #6. Options=Zones 1-8 (Default=None)
P67E
Monitor Mode Zone Alarms to Output #7. Options=Zones 1-8 (Default=None)
P68E
Monitor Mode Zone Alarms to Output #8. Options=Zones 1-8 (Default=None)
MAPPING 24 HOUR ZONE ALARMS TO OUTPUT
24 HOUR ZONE ALARM MAPPING TO OUTPUTS - P71E - P78E
When a 24 Hour zone is in alarm this block of addresses allows individual zones to be mapped to
selected outputs. The default setting is that zones 1-8 will turn on output 2 only when a 24 Hour
alarm occurs.
P71E
24 Hour Zone Alarms to Output #1. Options=Zones 1-8 (Default=None)
P72E
24 Hour Zone Alarms to Output #2. Options=Zones 1-8 (Default=1-8)
P73E
24 Hour Zone Alarms to Output #3. Options=Zones 1-8 (Default=None)
P74E
24 Hour Zone Alarms to Output #4. Options=Zones 1-8 (Default=None)
P75E
24 Hour Zone Alarms to Output #5. Options=Zones 1-8 (Default=None)
P76E
24 Hour Zone Alarms to Output #6. Options=Zones 1-8 (Default=None)
P77E
24 Hour Zone Alarms to Output #7. Options=Zones 1-8 (Default=None)
P78E
24 Hour Zone Alarms to Output #8. Options=Zones 1-8 (Default=None)
MAPPING DAY ZONES TO OUTPUTS
DAY ZONES TO OUTPUTS - P81E - P88E
When a Day zone is unsealed this block of addresses allows individual zones to be mapped to
selected outputs. The default setting is that no Day zones are mapped to any of the 8 outputs.
P81E
24 Hour Zone Alarms to Output #1. Options=Zones 1-8 (Default=None)
P82E
24 Hour Zone Alarms to Output #2. Options=Zones 1-8 (Default=None)
P83E
24 Hour Zone Alarms to Output #3. Options=Zones 1-8 (Default=None)
P84E
24 Hour Zone Alarms to Output #4. Options=Zones 1-8 (Default=None)
P85E
24 Hour Zone Alarms to Output #5. Options=Zones 1-8 (Default=None)
P86E
24 Hour Zone Alarms to Output #6. Options=Zones 1-8 (Default=None)
P87E
24 Hour Zone Alarms to Output #7. Options=Zones 1-8 (Default=None)
P88E
24 Hour Zone Alarms to Output #8. Options=Zones 1-8 (Default=None)