Page 30
duress alarm).
P230E Duress Digit -
Value 1-9 (Default = 0, Disabled)
SETTING REAL TIME CLOCK
The Real Time Clock is used to Time & Date stamp the events in the Event Buffer. Ensure this is set correctly at
the time of installation so that the events have the proper time and date associated with them. The clock is
programmed in 24 hour format (eg 00:00-23:59).
P401E Real Time Clock Hour/Minute -
Value 0-2359
P403E Real Time Clock Day of Week -
Value 1-7 (where 1 = Sunday, 2 = Monday, 3 = Tuesday, etc)
P405E Real Time Clock Date -
Value 1-31
P406E Real Time Clock Month -
Value 1-12
P407E Real Time Clock Year -
Value 0-99
SETTING DAYLIGHT SAVING START/FINISH
The real time clock can have preset automatic adjustments for the start & finish of daylight saving if applicable. If
a value of
“
0
”
is entered at addresses P408 & P411 then no daylight saving adjustments will apply. Otherwise set
up the parameters for the country concerned and the adjustments will become automatic every year.
P408E Daylight Saving Start Sunday -
Value 0-5 - Default = 1 (0=daylight saving start time disabled)
P409E Daylight Saving Start Month -
Value 1-12 - Default = 10
P410E Daylight Saving Start Hour -
Value 0-23 - Default = 2
P411E Daylight Saving End Sunday -
Value 0-5 - Default = 3 (0=daylight saving end time disabled)
P412E Daylight Saving End Month -
Value 1-12 - Default = 3
P413E Daylight Saving End Hour -
Value 0-23 - Default = 3
When setting up a panel for the first time using daylight saving, you must ascertain whether daylight saving is
currently ACTIVE. If it is you must enter in P414E then 1E to tell the panel that daylight saving is ON to sync the
panel to daylight saving mode. If this is not done then when daylight saving finishes the panel will not adjust the
clock.
P414E Daylight Saving is Active (If LED #1 is On, Daylight Saving is currently active)
RESTORE FACTORY DEFAULTS
This address (P620E) is used to return the panel back to factory default settings.
P620E Restore Factory Defaults
RESTORING SELECTED DEFAULTS
P621E Restore User Codes to Default only.
P622E Restore all Program Addresses from 20-199 to Default
P623E Restore all Program Addresses from 200-399 to Default
P624E Restore all Program Addresses from 500-599 to Default
P625E Restore all Radio & Pendant codes to Default
CLEAR ALARM MEMORY BUFFER
This address (P626E) is used to clear the panels alarm memory buffer.
P626E
Clear Alarm Memory Buffer
WALK TEST MODE
This address (P627E) is used to enable walk-test mode while in installer program mode. By pressing
P627E at the keypad, the keypad buzzer will beep at 1 second intervals to indicate walk-test mode is
active. By walking past all of the detectors connected to the system and activating them, the
associated zone light will latch up at the keypad to allow verification that all zones are working
properly. By pressing the
“
Program
”
or
“
Enter
”
buttons, walk-test mode can be terminated and normal
programming resumed.