Page 20
PARTITION
“
B
”
OUTPUT OPTIONS
PARTITION
“
B
”
OUTPUT OPTIONS - P121E - P128E
This block of addresses sets a number of output options which are specific and unique to the operation of partition
or Area "B". Activity in Areas "A" will have no direct effect on the options set at these addresses.
P121E
1E
Arm status to output- Default off
2E
Monitor Mode on status to output- Default off
3E
Disarm status to output- Default off
4E
Pendant chirps for Arm to output - Default off
5E
Pendant chirps for Monitor Mode On to output - Default off
6E
Pendant chirps for Disarm to output - Default off
7E
Pulse on Arming to output - Default off
8E
Pulse on Disarming to output - Default off
Option 1
Arm indication to output
- This option will turn the output on when Area "B" is armed. The output
will turn on at the start of the exit delay and turn off when the Area is disarmed. The output reset time
should be set to zero.
Option 2
Monitor Mode On indication to output
- This option will turn the output on when Area "B" Monitor
Mode is armed. The output will turn on at the start of the exit delay and turn off when Monitor Mode is
disarmed. The output reset time should be set to zero.
Option 3
Disarm indication to output
- This option will turn the output on when Area "B" is Disarmed. The
output will turn on when the Area
“
B
”
is disarmed and turn off when the Area is Armed or in Monitor
Mode. The output reset time should be set to zero.
Option 4
Pendant Chirps for Arm to output
- This option will map two short pulses (Chirps) to the output
when Area "B" is armed via a radio key (Pendant) ,( the length of the pulses is set by the pulse timer
P221E-P228E).
Option 5
Pendant Chirps for Monitor Mode On to output
- This option will map two short pulses (Chirps) to
the output when Area "B" Monitor Mode is set via a radio key (Pendant) ,( the length of the pulses is
set by the pulse timer P221E-P228E).
Option 6
Pendant Chirps for Disarm to output
- This option will map four short pulses (Chirps) to the output
when Area "B" is Disarmed via a radio key (Pendant) ,( the length of the pulses is set by the pulse
timer P221E-P228E).
Option 7
Pulse on Arming to output
- This option will map a pulse to the Output each time Area"B" is armed
( the length of the pulses is set by the pulse timer P221E-P228E).
Option 8
Pulse on Disarming to output
- This option will map a pulse to the Output each time Area"B" is
disarmed ( the length of the pulses is set by the pulse timer P221E-P228E).
Note: P122E through P128E are as above but applied to outputs 2-8
PROGRAMMING ZONE DOUBLING & EOL OPTIONS
SINGLE ZONE EOL OR DUAL ZONE INPUT (4 or 8 zones)
-
P130E - Default=1-4 On
P130E 1-8E
Single Zone EOL or dual zone input
- This option is used to define the Elite as a 4 zone
panel with or without EOL (End of Line Resistors) or an 8 zone panel. Options 1-4 relate to
zones 1-4 respectively and decide whether the zone input requires an end of line resistor or
just a short or open circuit to seal the zone. If the LED
’
s are
OFF
(Type 1 Drawing on Page 5 )
then a short on the input is all that is needed to seal the input. If the LED
’
s 1-4 are
ON
(Type 2
Drawing on Page 5 ) then the input requires a 2k2 resistor to seal the zone. Options 5-8 relate
to zone inputs 1-4 respectively and allow
“
Zone Doubling
”
to be turned on for a particular input.
When a zone has been assigned "Zone Doubling" the one input is used for both a low (1-4)and
a high (5-8) zone. When zone doubling is turned On, zone 1 input is used for zones 1 & 5,
zone 2 input is used for zones 2 & 6, zones 3 input is used for zones 3 & 7 and zone 4 input is