Page 35
P190E 1E
Listen-in Enabled when dialing only and in Disarmed State - Default off
2E
Listen-in Enabled when dialing only and in Armed State - Default off
3E
Listen-in Enabled when dialing only and in Monitor Mode - Default off
4E
Listen-in Enabled through the entire call only in Disarmed state - Default off
5E
Listen-in Enabled through the entire call only in Armed State - Default off
6E
Listen-in Enabled through the entire call only in Monitor Mode - Default off
7E
Listen-in Enabled when the panel answers a call - Default off
8E
Listen-in on at All Times - Default off
PROGRAMMING TELEPHONE NUMBERS
The panel can be programmed with up 4 telephone numbers. The numbers can be up 16 digits long. Dial modifiers
such as Pause can be programmed into the number sequence as per the chart below. See the table on page 32 for
more information on the special telephone number characters/modifiers.
LED KEYPAD LCD KEYPAD FUNCTION TO BE PROGRAMMED LED KEYPAD INDICATION
BUTTON BUTTON
“
Panic
”
Control 2
#
READY/EXCL
“
Memory
”
Control 3
*
SYSTEM
“
Control
”
Control 4 2.5 sec Pause TROUBLE
“
Arm
”
Control 5 Wait for 2nd Dial tone READY/EXCL & SYSTEM
“
Monitor
”
Control 6 5 sec Pause READY/EXCL & TROUBLE
P501E Telephone # 1 -
Value = 1-16 digits
P502E Telephone # 2 -
Value = 1-16 digits
P503E Telephone # 3 -
Value = 1-16 digits
P504E Telephone # 4 -
Value = 1-16 digits
MAXIMUM RE-TRIES PER TELEPHONE NUMBER
The addresses (P245E-P248E) are used to select the maximum number of dial attempts the panel will make for each
telephone number
P245E
Maximum Dial Attempts for Ph # 1 -
Value 0-99 (Default = 20)
P246E
Maximum Dial Attempts for Ph # 2 -
Value 0-99 (Default = 20)
P247E
Maximum Dial Attempts for Ph # 3 -
Value 0-99 (Default = 20)
P248E
Maximum Dial Attempts for Ph # 4 -
Value 0-99 (Default = 20)
PROGRAMMING TELEPHONE NUMBER REPORT FORMAT
This block of addresses (P241E - P244E) are used to set the reporting format which will be sent when an alarm
occurs for each of the telephone numbers.
P241E-Telephone #1 Options 1E
Contact ID
(Default = 1)
2E
Domestic Dial
3E
Pager
4E
Voice Dialer
5E
4 + 2 (Pulsed) 10 pps (1400 hz Handshake, 1800 hz transmit Tone)
6E
4 + 2 (Pulsed) 10 pps (1400 hz Handshake, 1900 hz transmit Tone)
7E
4 + 2 (Pulsed) 10 pps (2300 hz Handshake, 1800 hz transmit Tone)
8E
4 + 2 (Pulsed) 10 pps (2300 hz Handshake, 1900 hz transmit Tone)
9E
4 + 2 (Pulsed) 20 pps (1400 hz Handshake, 1800 hz transmit Tone)
10E
4 + 2 (Pulsed) 20 pps (1400 hz Handshake, 1900 hz transmit Tone)
11E
4 + 2 (Pulsed) 20 pps (2300 hz Handshake, 1800 hz transmit Tone)
12E
4 + 2 (Pulsed) 20 pps (2300 hz Handshake, 1900 hz transmit Tone)
13E
4 + 2 DTMF
Option 1
Contact ID
- If this option is set for the telephone number, the panel will send a Contact ID message to a
Monitoring Station.
Option 2
Domestic Dial
- If this option is set for the telephone number, the panel is expecting to dial a residential
telephone number when an alarm occurs. The message sent consists of a siren tone over the phone to
Elite the person called that an alarm is in progress. The alarm can be cancelled by the person called by
pressing any button on a touch tone phone during the quiet period. If the alarm is cancelled by a valid
Содержание Elite Version 8D
Страница 56: ...Page 56 ...