Software changes with the Elite 8D V8.61 (Nov 2001)
There have been a couple of changes to the panel to allow new features. These changes are
documented below so that the differences between this version of the panel and earlier versions
( software version V8.60 and below) can be identified.
The changes are;
1) A new event has been added to the event memory. When viewing the alarm events in memory mode there is a new
“
System
”
event which is
“
the dialer failed to get a kiss-off
”
. The event is displayed on the LED keypad as a system # 8 event (refer to the first
table on page 9).
2) A new feature has been added to the Monitor mode arming sequence. When arming monitor mode all exit and entry delays will
apply as programmed, however if the
“
Enter
”
button is pressed after arming monitor mode, then all exit and entry delays will be
cancelled for that armed cycle making everything instant.
3) A new program address has been added, P169E. This address provides three new options, see page 28 for details on these new
features.
4) The monitoring account numbers have moved from P332E (Area A account) & P333E (Area B account) to P506E (Area A) &
P507E (Area B). This change has been made to allow the letters B,C,D,E & F to be programmed into the account codes ( see
page 38 for details).
5) There has been a change to the way 24 hour alarms can be reported if using Domestic or Voice alarm modes. Option # 6 at
address P188E now can enable or fully disable 24 hour alarm reports in these two modes. In earlier software versions a 24 hour
alarm would always report an alarm in Domestic or Voice mode if the alarm was armed but could also be programmed to report
when disarmed as well. Now if option 6 is OFF there will be NO 24 hour alarms reported. If option 6 is ON then 24 hour alarms will
ALWAYS report regardless of the Arm/Disarm state.
6) There has been a new option added at address P188E, option #7. This option now allows the ability to control whether monitor
mode zone alarms will be reported via the dialer or not. If option 7 is turned ON, all monitor mode zone alarms will report via the
dialer, if OFF then no monitor mode zone alarms will be sent. This option is essentially designed to work in combination with option
2 at P188E. If full reporting of the part set alarm state (Monitor Mode) is required then option 2 & 7 will be turned on. If alarms only
are required for the part set mode then option 2 will be off and 7 on (this inhibits the arm/disarm report that may not be required in
a residential situation). Finally, if both options 2 & 7 are off then the part set mode is purely a local audible alarm with not alarm
reporting via the dialer.
7) There is a new zone configuration in the panel. This new option allows zone doubling to occur (4k7 & 8k2 Resistors) without the
need to use the 2k2 tamper resistor. When using this configuration an open or short circuit on the input will result in both zones
being un-sealed but NO zone tamper (refer to the drawing on page 5).
8) The Radio Pendant Panic alarm would always cause the keypad buzzer to sound as well when the alarm was activated. The radio
pendant panic alarm is now linked to the keypad panic alarms at address P175E. If all of the LEDS are Off at address P175E then
any Keypad or Radio Pendant generated panic alarms will not cause the keypad buzzer to sound (silent panic alarm). If the LEDS
are on at address P175E then the buzzer will sound when one of these alarms is generated (audible panic alarm).