Page 41
P261E Medical Alarm Voice Message Number -
(Default = 1)
P262E Battery Low Voice Message Number - (
Default = 1)
START MESSAGE NUMBER FOR DTMF CONTROL
This address (P250E) sets the start message for the DTMF remote control messages. The remote control messages
are set in a fixed sequence (refer to the addendum sheet supplied with the 90 second voice board for this list). If the
voice board is being used to indicate alarms using voice messages and DTMF remote control is also being used, the
alarm messages must be recorded first. When all alarm messages have been recorded you can then record the
remote control messages eg if you have 9 alarm messages recorded before the remote control messages, the value
entered at this address must be 10. A value other than
“
0
”
must be entered at this address for the function to work.
P250E Start of DTMF Remote Control Messages -
(Default = 0) Value= 0-99
DTMF REMOTE CONTROL CODES
This block of addresses (P334E - P337E) are used to program the 4 digit DTMF Remote Control Codes. These
codes allow a valid user to set or unset the alarm, turn outputs On or Off or enable the microphone input from a
remote telephone. Please refer to the User Operating guide or the addendum sheet supplied with the voice board for
the full operational sequence.
P334E Remote Control Code for Area
“
A
”
-
(Default = 0)
P335E Remote Control Code for Area
“
B
”
-
(Default = 0)
P336E Remote Control Code for Output Control -
(Default = 0)
P337E Remote Control Code to Enable the Microphone Input -
(Default = 0)
AUTO-ANSWER RING COUNT
The auto-answer ring count is the number of rings the panel must count before answering an in-coming call. For Fax
defeat to work the auto-answer ring count must be set to a number other than
“
0
”
. (typically 25 rings)
P249E Auto-answer Ring Count -
Value 0-99 (0= Auto-answer disabled) - Default = 25
MAINS FAIL REPORTING DELAY
This address (P319E) is used to set a timer that delays the reporting of Mains Failure to a Monitoring Station. If the
mains voltage returns before the timer expires then no report is sent.
P319E Mains Failure Report Delay -
Value 0-9999 Seconds (Default = 600)
SETTING DIALER TEST REPORT PARAMETERS
This option sets the days of the week and the time when an automatic test report is sent to a central monitoring
station. PLEASE NOTE: If daylight saving adjustments are set (P408-P413) do not set the value at P402 to be a
value between 1-3 am otherwise unwanted results will occur at the start & finish of daylight saving.
Also, if a
Domestic or Voice mode alarm is initiated but not reset or kissed off, when the test time comes around the
dialer will attempt to report the event/s again. To prevent this from happening, turn off ALL days at P404E.
P402E Automatic Test Report Hour/Minute -
Value 0-2359
P404E Automatic Test Report Day/s of Week -
Value 1-7 (where 1 = Sunday, 2 = Monday, 3 = Tuesday, etc)
UPLOAD/DOWNLOAD SITE CODE NUMBER
The upload/download site code number must be entered if the panel is set for auto-answer as this provides a security
access level to the panel. The number can be up to 8 characters in length. Valid characters for this number are 0-9,
B-F (refer to the chart on page 32).
P505E Site Code Number -
8 characters
Содержание Elite Version 8D
Страница 56: ...Page 56 ...