Page 27
7E
Delayed Panic Alarm (1.5 Seconds) - Default off
8E
Ness Battery Low - Default off
Option 1
Turn Output On
- This option allows the pendant to turn an output on. The output the pendant will
turn On is programmed at address P101E-P108E. If the output reset time is set to Latched operation
(set to
“
0
”
) then you must also program Option 2 to the pendant to allow for turning the output Off.
Option 2
Turn Output Off
- This option allows the pendant to turn an output off. The output the pendant will
turn Off is programmed at address P101E-P108E. For this option to work, option 1 above must also
be assigned to the pendant to allow the pendant to first turn the output on before it can turn it off.
Option 3
Visonic Powercode Battery Low -
If a Visonic Powercode Transmitter with battery low monitoring is
used on the Elite, setting this option will allow the battery signal to be correctly recognised.
Option 4
Spare
Option 5
Report Panic to Dialer-
This option enables a panic alarm from a pendant to be sent via the dialer to
a Monitoring Station.
Option 6
Immediate Panic Alarm -
If this option is on, pressing the pendant button will produce a pendant
panic alarm. The Panic alarm can also be silent at the keypad or sound the keypad buzzer (see
P175E)
Option 7
Delayed Panic Alarm-
If this option is on, the pendant button must be pressed continuously for 1.5
seconds or longer to produce a pendant panic alarm.
Option 8
Ness Battery Low -
If using a Ness pendant with battery low reporting, this option must be turned on
to allow the battery low signal to be recognized properly.,
Note: P162E through P168E are as above but applied to pendants 2-8
KEYPADS WITH LED
’
S OFF WHEN ARMED
This option allows the keypad LED
’
s to be turned off at any keypad when the system is fully or partially armed.
P169E
Keypads With LED
’
s Off When armed -
Option Keypad 1-8 (Default = None)
KEYPAD PARTITION ASSIGNMENT
A keypad must be assigned to a Partition before it can control the Partition (ie to allow Arm/Disarm facilities).
P171E
Keypads Assigned to Partition
“
A
”
-
Option Keypad 1-8 (Default = All keypads 1-8)
P172E
Keypads Assigned to Partition
“
B
”
-
Option keypad 1-8 (Default = None)
KEYPADS WITH PANIC BUTTON ENABLED
The panic button on all keypads can be set for delayed or instant operation. If you do not want the
Panic function enabled at any of the keypads you can disable the operation at this address. This
option may be useful where a keypad has to be installed in a public area.
P173E
Keypads with the Panic Button Enabled -
Option keypad 1-8
(Default = All keypads 1-8)
KEYPADS WITH BUTTONS 1&3 PANIC ENABLED
An alternative Panic function to the dedicated panic button is to press the keypad buttons 1&3
simultaneously. If you do not want this Panic function enabled at any of the keypads you can disable
the operation at this address. This option may be useful where a keypad has to be installed in a
public area.
P174E
Keypads with the Panic Buttons 1&3 Enabled -
Option keypad 1-8
(Default = None)
KEYPAD & RADIO PANIC ALARM TO KEYPAD BUZZER
The two Keypad panic functions (P173E or P174E) plus the Radio Panic Alarms can be audible or
silent at the keypads. If a silent panic is required the option must be turned off at this address. For an
audible Panic Beep at the keypad/s turn this option on.
Содержание Elite Version 8D