Page 33
communication with a modem is established.
Option 8
Bell 103 or V21 -
The dial up panel to PC link can be established using either Bell 103 or V21. If the
auto-detect function at option 7 does not result in the best format for your modem then you can force the
panel to only communicate in one format. If the LED is off the format is Bell103, LED on means V21.
DIALER REPORTING OPTIONS
“
A
”
This address (P186E) is used to enable or disable various alarm reports to the Dialer.
P186E 1E
Report Duress Alarm - Default on
2E
Report Mains Fail - Default on
3E
Report Battery Low - Default on
4E
Report Radio Battery Low - Default on
5E
Report System Tamper - Default on
6E
Report Telephone line Failure - Default on
7E
Report Supervised Radio Fault - Default on
8E
Report Zone Inactivity Alarm - Default on
Option 1
Duress Alarm to Dialer -
If a duress alarm is created the panel can report the unsetting of the alarm
under duress to a central monitoring company if this option is on.
Option 2
Report Mains Fail -
If a mains failure is detected the panel can report this alarm to a central monitoring
company if this option is on.
Option 3
Report Battery Low -
If a battery low is detected the panel can report this alarm to a central monitoring
company if this option is on.
Option 4
Report Radio Battery Low
- If a Radio battery low is detected the panel can report this alarm to a
central monitoring company if this option is on.
Option 5
Report System Tamper -
If a control panel tamper is detected the panel can report this alarm to a
central monitoring company if this option is on.
Option 6
Report Line Failure -
If a telephone line failure is detected the panel can report this alarm to a central
monitoring company if this option is on.
Option 7
Report Supervised Radio Fault
- If a supervised radio device fails to report to the panel within a
preset time then a radio failure is registered. If this option is turned on then the alarm will be reported to the
monitoring company.
Option 8
Report Zone Inactivity Alarm
- If a Zone is monitored for Inactivity (P150E) and the inactivity timer for
that zone times out (P240E) an alarm will be generated. If this option is turned on then the alarm will be
reported to the monitoring company.
DIALER REPORTING OPTIONS
“
B
”
This address (P187E) is used to enable or disable various alarm reports to the Dialer.
P187E 1E
Report Keypad Panic Alarms - Default on
2E
Report Keypad Manual Fire Alarms (4&6) - Default on
3E
Report Keypad Manual Medical Alarms (7&9) - Default on
4E
Spare
5E
Spare
6E
Spare
7E
Spare
8E
Spare
Option 1 Report Keypad Panic Alarms - If the single button
“
Panic
”
or the 2 button
“
1&3
”
Panic alarm features
are enabled then turning this on option allows the Panic Alarm to be sent via the dialer to a monitoring
station.