Page 26
RADIO PENDANT OPTIONS
“
A
”
RADIO PENDANT OPTIONS
“
A
”
-
P151E-P158E
This block of addresses (P151E - P158E) are used to select the operational settings for each of the 8 radio
pendants. Functions such as arm only, disarm only or both can be selected for each pendant independently.
P151E-Pendant #1 Options 1E
Assigned to Partition
“
A
”
- Default on
2E
Assigned to Partition
“
B
”
- Default off
3E
Pendant can Arm the system - Default on
4E
Pendant can Disarm the system - Default on
5E
Pendant can turn Monitor Mode On - Default off
6E
Pendant can turn Monitor Mode Off - Default off
7E
Spare - Default off
8E
Pendant is disabled if panel is in alarm - Default off
Option 1
Assigned to Partition
“
A
”
- This option assigns the pendant to partition
“
A
”
. The pendant must be
assigned to at least one partition to allow it to perform arm/disarm functions. The pendant can be
assigned to both partitions if required.
Option 2
Assigned to Partition
“
B
”
- This option assigns the pendant to partition
“
B
”
. The pendant must be
assigned to at least one partition to allow it to perform arm/disarm functions. The pendant can be
assigned to both partitions if required.
Option 3
Pendant can Arm
- This option assigns the Arm function to a pendant. The partition/s it will arm has
to be selected at options 1 & 2.
Option 4
Pendant can Disarm
- This option assigns the Disarm function to a pendant. The partition/s it will
disarm has to be selected at options 1 & 2.
Option 5
Pendant can turn Monitor Mode On -
This option assigns the Monitor Mode Arm function to a
pendant. The partition/s it will arm has to be selected at options 1 & 2. If Monitor Mode arming is to
be used for this pendant then Options 2 & 3 should be turned off.
Option 6
Pendant can turn Monitor Mode Off -
This option assigns the Monitor Mode Disarm function to a
pendant. The partition/s it will disarm has to be selected at options 1 & 2. If Monitor Mode disarming
is to be used for this pendant then Options 2 & 3 should be turned off.
Option 7
Spare
Option 8
Pendant Disabled if panel is in Alarm -
This option stops the pendant from working while the panel
is in alarm. This feature should only be set if you feel that a pendant with disarming functions could
be prone to misuse in an alarm condition.
Note: P152E through P158E are as above but applied to pendants 2-8
RADIO PENDANT OPTIONS
“
B
”
RADIO PENDANT OPTIONS
“
B
”
-
P161E-P168E
This block of addresses (P161E - P168E) are used to select output control and Panic options for each of the 8
radio pendants. To prevent confusion, if a pendant is set to control an output or provide instant Panic, then you
should turn off any Arm or Disarm options at addresses P151E-P158E.
P161E-Pendant #1 Options 1E
Turn output ON - Default off
2E
Turn output OFF - Default off
3E
Visonic Powercode Battery Low - Default off
4E
Spare - Default off
5E
Report Pendant Panic To Dialer - Default off
6E
Immediate Panic Alarm - Default off
Содержание Elite Version 8D
Страница 56: ...Page 56 ...