Page 54
Contact ID Code Summary
In addition to the programmable Contact ID code assignments defined at P 321E - P331E there are a number of
event codes with extensions pre-defined as listed below. This extensions list is for your reference only and can not
be re-assigned.
Event Code Extension Comment
Cabinet Tamper 137 000 Panel & Sat Tamper etc
Zone Tamper - Low (short circuit) 137 001 to 004 Zone Input 1-4
Zone Tamper - High (open circuit) 137 005 to 008 Zone Input 1-4
Keypad Panic (or 1&3) 120 001 At keypad #1
through to 008 At keypad #8
Keypad Fire (4&6) 110 001 At keypad #1
through to 008 At keypad #8
Keypad Medical (7&9) 100 001 At keypad #1
through to 008 At keypad #8
Arm by "ARM key (Quick Arm) 408 000
Arm by user code 401 001 User #1
through to 010 user #10
Arm by Radiokey 400 001 Radio User #1
through to 008 Radio User #8
Arm by Command Control (remote set) 407 000 Command Control arm/disarm
Arm by Keyswitch 409 001 Area
“
A
”
Keyswitch Arm/Disarm
409 002 Area
“
B
”
Keyswitch Arm/Disarm
Arm by Up/Download 407 000 Remote PC arm/disarm
Radiokey Panic 120 001 Radiokey pendant #1
008 Radiokey pendant #8
Radio PIR / Reed Switch Activation 130 001 Zone 1
through to 008 Zone 8
System Battery Low 302 000 Control Panel Battery low
Mains Fail 301 000 230v mains to control panel lost
Radio PIR / Reed Switch Battery Low 384 001 Zone 1
through to 008 Zone 8
Radio PIR Supervised Alarm 381 001 Zone 1
through to 008 Zone 8
Zone Inactivity Alarm 391 001 Zone 1
through to 008 Zone 8
Radiokey Battery Low 384 021 Radiokey #1
022 Radiokey #2
023 Radiokey #3
through to 028 Radiokey #8
TEST Calls 602 000 24 hour test
Zone Excludes 570 001 Exclude Zone 1
through to 008 Exclude Zone 8
Phone Line Failure 351 000 Reported when line is restored
Monitor Mode (part set) 441 000 Arm by
“
Monitor
”
Button
001 User 1
through to 010 User 10
Duress Alarm 121 001 Duress at Keypad #1
through to 008 Duress at keypad #8
Содержание Elite Version 8D
Страница 56: ...Page 56 ...