Page 15
zone led (LEDS 1-8) will be on. The operator can now press a button relating to the output/s they
wish to control eg pressing the
“
1
”
button will turn output 1 on or off, The
“
2
”
button for output 2 etc.
When an output state is changed the zone LED will indicate the change of state. When finished the
operator then presses the
“
Enter
”
button to cancel the Control mode and return to normal. To
operate the output/s via a telephone please refer to the instructions supplied with the voice board.
Option 7
Flash 24 hour alarm
- If a 24 hour zone activates the alarm this option will cause the output to
flash at a rate equal to the value set for the pulse timer(P221E-P228E).
Option 8
Day Zones Linked to Pulse Timer
- Day Zones programmed to this output will pulse at the pulse
timer rate (P221E-P228E) for the duration of the day zone to output timer (P211E-P218E)
P32E - P38E
As per P31E above for Outputs 2-8
PROGRAMMING OUTPUT OPTIONS cont.
OUTPUT OPTIONS B - P41E - P48E
In this block of addresses P41E relates to output #1, P42E relates to output #2 etc
P41E 1E
Pendant Panic to Output - Default on
2E
Keypad Panic to Output - Default on
3E
Keypad Fire to Output - Default off
4E
Keypad Medical to Output - Default off
5E
Cabinet Tamper to Output - Default on
6E
Duress Alarm to Output - Default off
7E
Mains Fail to Output - Default off
8E
Battery Low to Output - Default off
Option 1
Pendant Panic to Output
- This option is used to map the operation of the Radio Pendant panic
button to an output i.e. when the Radio Panic button is pressed any output with this option enabled
will turn on.
Option 2
Keypad Panic to Output
- This option is used to map the Keypad Panic Button, or the 2 button
Panic function to an output. Keypad Panics are generated when a user presses the Panic Button or
buttons
1 & 3 Simultaneously
at the keypad.
Option 3
Keypad Fire to Output
- This option is used to map the manual Keypad Fire alarm function to an
output. The keypad Fire alarm is generated when a user presses buttons
4 & 6 Simultaneously
at
the keypad.
Option 4
Keypad Medical to Output
- This option is used to map the manual Keypad Medical alarm
function to an output. The keypad Medical alarm is generated when a user presses buttons
7 & 9
Simultaneously
at the keypad.
Option 5
Cabinet Tamper to Output
- This option is used to map activations of the common Tamper Input
to an output. This common tamper input is normally used to monitor the panel cabinet and satellite
tamper switches.
Option 6
Duress Alarm to Output
- This option will map the Duress Function to an output. Programming of
the Duress Digit is at address P230E.
Option 7
Mails Fail To Output
- A mains failure will be indicated at this output when option 7 is enabled at
this address. The Alarm Reset Timer must be set to
“
0
”
when this option is used.
Option 8
Low Battery
- A battery Low condition will be indicated at this output when option 8 is enabled at
this address. The alarm reset timer must be set to
“
0
”
when this option is used.
P42E - P48E
As per P41E above for Outputs 2-8